Third Party Verification Claim
Page 64 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
45.3
To determine compliance with the requirements in
45.1 and 45.2, the test is to be made using a 500
volt-ampere or larger capacity testing transformer,
the output voltage of which is essentially
sinusoidal and can be regulated. The applied
potential is to be increased from zero until the
required value is reached and is to be held at that
value for 1 minute. The increase in the applied
potential is to be at a substantially uniform rate
and sufficiently rapid to be consistent with its value
being correctly indicated by a voltmeter
P
45.4
An appliance provided with a normally-open
immersion protective device is to be tested as
follows. The appliance is to be connected to a
supply circuit of rated voltage, the protective
device is to be reset (closed), an on-off switch of
the appliance is to be in the
off position, and the test potential is to be
applied between each supply circuit conductor and
exposed dead-metal parts as described in 45.1 –
45.3
P
46
Abnormal Operation Tests
P
46.1
General
P
46.1.1
A hair dryer shall not cause ignition of any material
or emission of flame, sparks, molten metal, or
similar result when operated under the conditions
described in
N/A
46.1.2, 46.1.3, and 46.2.1 – 46.4.6.13 for a
hand-supported type, or
N/A
46.1.2, 46.1.3, and 46.2.1 – 46.3.4 for other than a
hand-supported type
N/A
The dryer shall not collapse or experience
displacement of any part that results in a risk of
fire or electric shock, such as short-circuiting or
grounding.
N/A