Third Party Verification Claim
Page 61 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
44.3.2
With regard to 44.3.1, air intake openings provided
in the gripping area of the handle that may be
blocked by the user’s hand, such as those shown
in Figure 44.2, are to be blocked such that all
openings in three or fewer quadrants of the
handle circumference will be blocked. (If there are
openings in all quadrants, those in one quadrant
are to be left open. Openings provided in the base
of a cylindrical handle, such as those shown in
Figure 44.3, are not considered likely to be
blocked by the user’s hand and are not to be
blocked.) Three-fourths of the air outlet openings
in the barrel are also to be blocked. For example,
in a unit provided with eight parallel rows of
openings in the length of the barrel, two adjacent
rows are to be left unblocked
N/A
44.4
Hair-drying appliances
N/A
44.4.1
For a floor- or table-supported hair dryer having
a bonnet or rigid hood and provided with an
adjustable temperature control, temperatures are
to be recorded after 15 minutes of operation with
the control set for maximum heating and with the
dummy head in the position normally occupied by
the human head under the dryer. The control is
then to be set for the coolest condition that results
in an average temperature of no less than 43°C
(109.4°F) on the top and sides of the dummy
head, and operation is to be continued until all
temperatures become constant. The dummy head
is then removed, the control is to be reset for
maximum, and operation is to be continued until
temperatures become constant. A hair dryer that
has a flexible air tube that can be separated from
the bonnet or rigid hood is also to be tested under
the conditions described in 44.5.1
N/A
44.4.2
For a hair dryer that is provided with a rigid hood,
the dummy head is to be located so that its
surface will be a minimum of 1 inch (25.4 mm)
from the interior surface of the hood and so
positioned in the hood that maximum temperatures
will result
N/A
44.4.3
A floor-supported hair dryer not provided with an
adjustable temperature control is to be operated
continuously (with the dummy head in place) until
all temperatures become constant
N/A
44.5
Hand-supported hair dryers
N/A