Third Party Verification Claim
Page 60 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
44..2.1
The appliance is to be loaded with the maximum
recommended amount of wax and operated
continuously until constant temperatures have
been reached. An adjustable temperature control
is to be set for maximum heating. If the appliance
has several heat settings for different functions
(as noted in 9.3.3), it is to be operated at the
highest heat setting, as well as at the maximum
setting intended to maintain the molten wax at the
temperature for application to the skin
N/A
44.2.2
The wax temperature is to be measured by means
of a thermocouple immersed beneath the surface
of the wax to a depth of approximately one-half of
the total depth, at the approximate center of the
reservoir. The wax is to be slowly and continuously
stirred while temperatures are being recorded. For
depilatory appliances having self-contained wax
applicators (no open reservoirs), thermocouples
are tobe inserted into the wax applicators to a
depth of approximately one-half of the total depth
of the wax
N/A
44..2.3
In addition to complying with the requirements
specified in 9.3.1, 9.3.2, and 44.1.1, the visible
overheat condition indicator, when required as
specified in 9.3.3(b), shall function when the
waxtemperature exceeds 75°C (167°F)
N/A
44.3
Heated air curling irons and brushes
N/A
44.3.1
A heated air curling iron or brush is to be operated
continuously with all air intake and outlet openings
unrestricted until temperatures stabilize. The
appliance is then to be operated through 30
cycles, with one cycle consisting of one minute of
operation with the air intake and outlet openings
blocked as described in 44.3.2, followed by 10
seconds of operation with all air openings open
N/A
Exception: With the concurrence of all concerned,
the cycling portion of the test may be replaced with
30 minutes of continuous operation with the
openings blocked as described in 44.3.2
N/A