Third Party Verification Claim

Page 6 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
8.1.1
The frame and enclosure of an appliance shall be
sufficiently strong and rigid to resist the abuses
likely to be encountered during service. The
degree of resistance inherent in the appliance
shall preclude total or partial collapse with the
attendant reduction of spacings, loosening or
displacement of parts, and other conditions which
alone or in combination constitute an increase in
the risk of fire, electric shock, or injury to persons
P
8.1.2
Among the factors taken into consideration in
evaluating an enclosure for acceptability are its
P
Physical strength, Resistance to impact
N/A
8.2
Polymeric enclosures and parts
P
8.2.1
A polymeric enclosure shall comply with the
Standard for Polymeric Materials Use in
Electrical Equipment Evaluations, UL 746C
P
Exception: The Abnormal Operation Tests, Section
46, shall be applied in lieu of the abnormal and
severe conditions requirements specified in UL
746C. For the polymeric enclosure of an appliance
other than a hand-supported hair dryer, the use of
HB material may require additional abnormal or
severe conditions tests.
P
8.3
Metal enclosures
N/A
8.3.1
The minimum thickness of a metal enclosure shall
be as indicated in Table 8.1
N/A
8.4
Corrosion resistance
P
8.4.1
Iron and steel parts shall be made corrosion
resistant by painting, galvanizing, plating, or other
equivalent means if the malfunction of such
unprotected parts would result in a risk of fire,
electric shock, or injury to persons
P
Exception No. 1: In constructions in which the
oxidation of iron or steel due to the exposure of the
metal to air and moisture will not be appreciable
thickness of metal and temperature also being
factors surfaces of sheet steel and cast-iron
parts within an enclosure not required to be made
corrosion resistant
N/A
8.4.2
A container for liquid shall be made resistant to the
possible corrosive effect of the liquid intended to
be used in the container.
N/A
8.5
Accessibility of live parts
P
8.5.1
An electrical part of an appliance shall be located
or enclosed so that unintentional contact with any
uninsulated live part and internal wiring will be
prevented
P