Third Party Verification Claim
Page 55 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
One hour at 23.0 2.0°C (73.4 3.6°F) and a
relative humidity of 50 5 percent, followed by
N/A
42.3
Limited thermal aging
N/A
42.3.1
Five samples are to be conditioned for 300 hours
at the oven temperature determined from the
respective temperature index line in Figure 42.2, in
which the temperature index T is the measured
normal operating temperature of the coating
determined in accordance with 44.5, but no less
than 60°C (140°F). If agreeable to all concerned, a
longer time at a correspondingly lower
temperature may be used as determined in
accordance with Figure 42.2. After the
conditioning, the samples are to be brought to and
tested at a room ambient temperature of 23.0
2.0°C (73.4 3.6°F)
N/A
42.4
Short term aging
N/A
42.4.1
Five samples are to be conditioned for 56 days at
18.0 – 20.0°C (32.4 – 36.0°F) higher than the
maximum measured normal use temperature of
the coating determined in accordance with 44.5,
but no less than 85°C (185°F) in any case.
N/A
42.5
Humidity conditioning
N/A
42.5.1
Five samples are to be conditioned for 56 days at
35.0 2.0°C (95.0 3.6°F) and a relative humidity of
90 5 percent.
N/A
43
Power Input Test
P
43.1
The power input to an appliance marked with a
rating of 50 watts or less shall be within the
inclusive range of 75 – 110 percent of that rating. If
the marked rating is greater than 50 watts, the
power input shall be within the inclusive range of
90 – 110 percent of that rating
P
43.2
With respect to 43.1, the wattage of an appliance
marked with its electrical rating only in amperes
and volts will be assumed to be the product of
those two values
P
43.3
The power input to the appliance is to be
measured with the appliance at operating
temperature under full-load conditions, and while
connected to a circuit of a voltage in accordance
with 44.1.13. Control switches or the equivalent, if
provided, are to be set to give the maximum power
input. For an appliance having a preheat cycle of
operation as defined in 5.33, the maximum input
value measured during the preheat cycle, with the
appliance at room temperature at the beginning of
the measurement, is to be used to determine
compliance with the requirement specified in 43.1.
P