Third Party Verification Claim

Page 53 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
40.2
Conditioned hair dryers
N/A
40.2.1
The requirements specified in 40.1.2 40.1.7 are
to be applied to samples of a hair dryer provided
with an immersion detection that have been
subjected to one of the following tests (each test is
to be conducted)
N/A
Drape test, 46.2.1 46.2.3
N/A
Restricted air inlet test, 46.4.2.1 46.4.2.4
N/A
40.2..2
The tests on the conditioned samples are to be
conducted using the on-off switch position, the
heat-speed selector switch(es) position(s), the
supply circuit voltage and polarity, the water
resistivity, and the like as specified in 40.1.2 and
40.1.5, that resulted in the highest leakage
current and longest immersion detection trip time
determined in accordance with 40.1.3. The results
are acceptable if the immersion detection trips at a
current:
N/A
Less than 6 milliamperes or
N/A
Greater than 6 milliamperes in a period of time to
comply with the time and current relationship
specified in 40.1.1. The period of time is to be
measured from the moment the current flow
exceeds 6 milliamperes to the moment the current
ceases to flow. When the immersion detection
trips, the flow of current to ground is to cease
N/A
41
Dew Point Humidity Test
N/A
41.1
Three samples of a hair dryer provided with an
IDCI are to be conditioned in a chamber at a
temperature of 5 2°C (41 3.6°F) for at least
4 hours and then transferred to a humidity
chamber having a relative humidity of 86 2
percent at a temperature of 32 2°C (89.6
3.6°F). The transfer time is not to exceed 1
minute. The samples are to be energized by the
insertion of their attachment plugs into receptacles
of the voltage specified in 44.1.13. The on-off
switch of the hair dryer is to be in the off position.
The samples are to remain in the humidity
chamber for 15 minutes. The results are
acceptable if the IDCIs do not trip while in the
chambe
N/A
42
Conductive Coating Test
N/A
42.1
General
N/A