Third Party Verification Claim

Page 5 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
Exception: A user-resettable protective device may
be provided with a reset feature not having a test
function based on all of the following
N/A
The protective device complies with the Standard
for Tests for Safety-Related Controls Employing
Solid-State Devices, UL 991. If the computational
investigation is conducted, the maximum predicted
failure rate ( p) shall not exceed 1.5 failures per
million hours predicted. If the demonstrated
method is conducted, the test acceleration
multiplier shall be 5763
N/A
The instructions provided with the appliance alert
the user to the reset feature and how and when to
use it
N/A
The instructions provided with the appliance alert
the user to not reset and reuse the appliance
should the protective device trip as a result of
immersion
N/A
7.7
switch included for testing a user resettable
protective device shall be permanently marked
Test and Reset on or adjacent to the switch
actuators
N/A
7.8
After a protective device de-energizes current-
carrying parts, it shall not automatically reset
N/A
7.9
A protective device that is integral with the
attachment plug of a hand-supported hair-drying
appliance may be provided with a single outlet
convenience receptacle when all of the following
requirements are me
N/A
The convenience receptacle has a rating of 15
amperes, 125 volts and complies with the
Standard for Attachment Plugs and Receptacles,
UL 498
N/A
Exception No. 1: Flexible cord acceptable for use
with hand-supported hair dryers as specified in
Table 13.2 may be used.
N/A
7.10
With regard to 7.9(f), each output circuit shall be
considered if one is not representative of the other.
For example, the short circuit test shall be
conducted with each output short-circuited one at
a time. The dielectric voltage-withstand test
between line-connected circuits and load circuits
shall include both load circuits. The temperature
test shall be conducted with
N/A
The hair dryer load circuit and the convenience
receptacle each loaded to rated value and
N/A
The convenience receptacle loaded to 15 amperes
with no load connected to the hair dryer load
circuit
N/A
8
Frame and Enclosure
P
8.1
General
P