Third Party Verification Claim

Page 39 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
26.2.2
When conducting evaluations in accordance with
the requirements in the Standard for Insulation
Coordination Including Clearances and Creepage
Distances for Electrical Equipment, UL 840, the
following guidelines shall be used
N/A
A household appliance is to be categorized as
Overvoltage Category II. See Table 25.1
N/A
The applicable Material Group per Table 25.2
N/A
26.3
In order to apply Clearance B (controlled
overvoltage) clearances, control of overvoltage
shall be achieved by providing an overvoltage
device or system as an integral part of the product.
This voltage limiting device or system shall comply
with the Standard for Surge Protective Devices,
UL 1449
N/A
27
In order to apply Clearance B (controlled
overvoltage) clearances, control of overvoltage
shall be achieved by providing an overvoltage
device or system as an integral part of the product.
This voltage limiting device or system shall comply
with the Standard for Surge Protective Devices,
UL 144
N/A
27.1
All permanently connected appliances shall have
provision for the grounding of all exposed metal
parts that are likely to become energized
N/A
Exception: An appliance provided with a double-
insulation system, shall be constructed in
accordance with the Standard for Double
Insulation Systems for Use in Electrical
Equipment, UL 1097, and is not required to be
grounded
N/A
27.2
An appliance marked as double insulated shall not
be provided with a means for grounding
N/A
27.3
If a grounding means is provided on the appliance,
whether required or not, all exposed dead-metal
parts and all dead-metal parts within the
enclosure that are exposed to contact during any
servicing operation and that are likely to become
energized shall be reliably connected to the
grounding means
N/A
27.4
An equipment grounding conductor of a flexible
cord shall comply with all of the following
N/A
Finished to show a green color with or without one
or more yellow stripes
N/A
Conductively connected to
All exposed dead-metal parts that are likely to
become energized and
N/A
Exception: The grounding contact member of a
grounding attachment plug used on the power
supply cord of a portable hand-held, hand- guided,
or hand-supported appliance may be of the
movable, self-restoring type on circuits operating
at 150 volts or less between any conductor and
ground
N/A