Third Party Verification Claim

Page 35 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
24.2.3
In a wax depilatory appliance, an automatic- reset
temperature control shall be a calibrated control
endurance tested for at least 6,000 cycles of
operation and shall comply with all other
requirements applicable to limit controls in the
Standard for Limit Controls, UL 353, or the
requirements applicable to temperature- limiting
controls in the Standard for Temperature-
Indicating and -Regulating Equipment, UL 873.
The calibration requirements shall be as specified
for water- heater limit controls in UL 353 or water-
heater temperature-limiting controls in UL 873.
Compliance with the Standard for Automatic
Electrical Controls for Household and Similar Use,
Part 1: General Requirements, UL 60730-
1, and/or the applicable Part 2 standard from the
UL 60730 series fulfills the UL 873
requirements
N/A
24.2.4
A temperature sensing positive temperature
coefficient (PTC) or a negative temperature
coefficient (NTC) thermistor, that performs the
same function as an operating or protective control
shall comply with
N/A
The Standard for Automatic Electrical Controls for
Household and Similar Use; Part 1General
Requirements, UL 60730-1; and the Standard for
Automatic Electrical Controls for Household and
Similar Use; Part 2: Particular Requirements for
Temperature Sensing Controls,UL 60730-2- 9 with
Annex J or
N/A
The Standard for Thermistor-Type Devices, UL
1434
N/A
25
Controls End Product Test Parameters
N/A
25.1
General
N/A
25.1.1
Spacings of controls shall comply with the
electrical spacing, or clearances and clearance
distance requirements of the applicable control
standard as determined in Spacings, Section 26
N/A
25.1.2
Where reference is made to declared deviation
and drift, this indicates the manufacturers
declaration of the controls tolerance before and
after certain conditioning tests.
N/A
25.2
Auxiliary controls
N/A
25.2.1
Auxiliary controls shall not introduce a risk of
electric shock, fire, or personal injury
N/A
25.2.2
Auxiliary controls shall comply with the
requirements of this standard
N/A
Exception: An auxiliary control that complies
with a component standard(s) specified in 24.2 is
considered to fulfill this requirement.
N/A
25.3
Electronic Operating controls (regulating controls)
N/A