Third Party Verification Claim

Page 34 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
The Standard for Automatic Electrical Controls for
Household and Similar Use; Part 1: General
Requirements, UL 60730-1 except the Controls
Using Software requirements, Clause H 11.12.
N/A
24.1.10
Electronic protective controls that rely upon
software as a protective component shall comply
with one of the following
N/A
The Standard for Tests for Safety-Related
Controls Employing Solid-State Devices, UL 991;
and the Standard for Software in Programmable
Components, UL 1998 or
N/A
The Standard for Automatic Electrical Controls for
Household and Similar Use; Part 1: General
Requirements, UL 60730-1.
N/A
24.1.11
If a single malfunction or breakdown of an
electronic component, located in electronic
operating control, results in increased risk of injury
to persons, such as a loss of OFF control or
unexpected operation, this control shall comply
with the applicable requirements specified in
24.1.7 24.1.10. See 25.4
N/A
24.1.12
An electronic, auxiliary or operating control (e.g. a
non-protective control), the failure of which would
not increase the risk of fire, electric shock, or
injury to persons (i.e. burn injury), is not required
to comply with the requirements in
24.1.6 24.1.11, and is only required to be
subjected to the applicable requirements of this
standard
N/A
24.2
Electromechanical and electronic controls
N/A
24.2.1
A temperature control shall comply with one of the
following
N/A
The Standard for Temperature-Indicating and
Regulating Equipment, UL 873 or
N/A
The Standard for Automatic Electrical Controls for
Household and Similar Use; Part 1: General
Requirements, UL 60730-1; and the Standard for
Automatic Electrical Controls for Household and
Similar Use; Part 2: Particular Requirements for
Temperature Sensing Controls, UL 60730-2- 9
N/A
24.2.2
A temperature control installed in a hand-
supported hair dryer shall operate at not more than
8.3°C (15°F) above or below its rated operating
temperature. Compliance is determined by
subjecting the control, a sub- assembly including
the control, or the complete appliance to the
appropriate temperatures in an air oven
N/A