Third Party Verification Claim
Page 33 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
24.1.3
The overload and endurance tests of a
temperature controller consisting of a temperature
sensor and the associated control circuit for an
appliance having a preheat cycle shall be
conducted in the appliance, or under conditions
representative of those in the appliance, as
described in the Test of Automatic Controls,
Section 54. See 24.2.4
N/A
24.1.4
A temperature controller that controls the duration
of a preheat cycle by a timing circuit or by an
equivalent means without using a temperature
sensor is considered to be a temperature-
regulating control and shall comply with the
overload and endurance requirements specified
in the Test of Automatic
Controls, Section 54
N/A
24.1.5
Auxiliary controls shall be evaluated in accordance
with the applicable requirements of this standard
and the parameters in Controls – End Product Test
Parameters, Section 25 unless otherwise specified
in this standard. See 24.1.12
N/A
24.1.6
Operating (regulating) controls shall be evaluated
in accordance with the applicable component
standard requirements specified in 24.2, if
applicable, and the parameters in Controls – End
Product Test Parameters, Section 25, unless
otherwise specified in this standard. See 24.1.12
N/A
24.1.7
Electronic operating controls that rely upon
software for the normal operation of the end
product where deviation or drift of the control may
result in a risk of fire, electric shock, or injury to
persons, such as a speed control unexpectedly
changing its output, shall comply with one of the
following
N/A
The Standard for Tests for Safety-Related
Controls Employing Solid-State Devices, UL 991;
and the Standard for Software in Programmable
Components, UL 1998 or
N/A
The Standard for Automatic Electrical Controls for
Household and Similar Use; Part 1: General
Requirements, UL 60730-1
N/A
24.1.8
Protective (limiting) controls shall be evaluated in
accordance with the applicable component
standard requirements specified in
24.2 and if applicable, the parameters in Controls
– End Product Test Parameters, Section 25,
unless otherwise specified in this standard
N/A
24.1.9
Electronic protective controls that do not rely upon
software as a protective component shall comply
with one of the following:
N/A
The Standard for Tests for Safety-Related
Controls Employing Solid-State Devices, UL 991
or
N/A