Third Party Verification Claim
Page 29 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
Table 13.3 identifies the supply cord conductor
intended to be grounded.
N/A
22.3
An Edison-base lampholder shall not be used in
an appliance rated over 150 volts.
N/A
Exception: An Edison-base lampholder may be
used if the construction is such that live parts of
the lampholder and the lamp will not be exposed
to contact by persons when the screw shell of the
lamp is in contact with live parts of the lampholder
or if used on a three-wire Edison system
N/A
22.4
In determining compliance with the Exception to
22.3, the probe shown in Figure 8.1 shall be used
as described in 8.5.3
N/A
22.5
An Edison-base lampholder in an appliance rated
150 volts or less shall be constructed or installed
so that an uninsulated live part other than the
screw shell will not be exposed to contact by a
person removing or replacing a lamp during
intended service
N/A
Exception: This requirement is not applicable to an
appliance:
N/A
For which it is necessary to dismantle the
appliance or remove a cover plate or other part by
means of a tool to remove or replace a lamp or
N/A
That is permanently and legibly marked to indicate
that such relamping is to be done with the
appliance disconnected from the supply source
N/A
22.6
A 15- or 20-ampere attachment plug receptacle
intended for general use in an appliance shall be
of the grounding type. The grounding contact of
the receptacle shall be electrically connected to
dead metal that will be grounded when the
appliance is in use
N/A
22.7
Attachment plug receptacle shall comply with the
Standard for Attachment Plugs and Receptacles,
UL 498
N/A
22.8
The face of a receptacle that is less than 5/8 inch
(15.9 mm) wide or 7/8 inch (22.2 mm) long shall
project a minimum of 0.015 inch (0.38 mm) and a
maximum of 3/16 inch (4.8 mm) from the part of
the receptacle-mounting surface that is within a
rectangle 5/8 inch wide and 7/8 inch long, the
rectangle being symmetrically located about the
receptacle contacts
N/A
Exception: If the mounting surface for the
receptacle is electrically conductive, the face of the
receptacle shall project a minimum of 3/32 inch
(2.4 mm)
N/A
22.9
An appliance provided with one or more general
use receptacles shall not be equipped with a
flexible cord not smaller than 16 AWG (1.3 mm2)
N/A