Third Party Verification Claim
Page 28 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
20.1
If overcurrent conditions are likely to occur, the
appliance shall be provided with a circuit breaker
or fuse
P
20.2
Overcurrent protection at not more than 20
amperes shall be provided by means of a circuit
breaker or fuse in the appliance for each general
use receptacle circuit and each lampholder circuit
in the appliance, unless the appliance would be
correctly connected to a branch circuit rated at 20
amperes or less
P
20.3
The overcurrent protection specified in 20.2 shall
be of a type rated for branch circuit protection.
N/A
20.4
A fuseholder or circuit breaker provided as a part
of an appliance shall be of a type rated for the
particular application and shall not be accessible
from outside the appliance without opening a door
or cover. A fuseholder for a plug fuse shall be
constructed and installed so that an uninsulated
live part other than the screw shell will not be
exposed to contact by persons removing or
replacing a fuse
N/A
Exception: The operating handle of a circuit
breaker may project outside the enclosure.
N/A
20.5
For other than a hand-supported appliance, if the
handle of a circuit breaker is operated vertically
rather than rotationally or horizontally, the up
position of the handle shall be the on position
N/A
21
Thermal Cutoffs (Fusible Links)
N/A
21.1
If an appliance is provided with a thermal cutoff,
the cutoff shall open the circuit in the intended
manner without causing the short circuiting of live
parts and without causing live parts to become
grounded to the enclosure. This determination is to
be made in accordance with the test requirements
specified in the Test of Thermal Cutoffs (Fusible
Links), Section 55
N/A
21.2
A thermal cutoff shall comply with the Standard for
Thermal-Links – Requirements and Applications
Guide, UL 60691
N/A
22
Lampholders and Receptacles
N/A
22.1
Lampholders and indicating lamps integral with
lampholder shall comply with the Standard for
Lampholders, UL 496. A female screw shell used
as a holder for a heating element shall be of
copper or of copper alloy and shall be plated with
nickel or an equivalent oxidation-resistant metal
N/A
22.2
The circuit conductor of a power supply cord that
is intended to be grounded shall have the following
items connected to it:
N/A
The screw shell of an Edison-base lampholder and
N/A
The terminal or lead of a receptacle intended to be
grounded
N/A