Third Party Verification Claim

Page 27 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
18.1.5
Insulating material on which the opposite polarity
fixed contacts of a hand-held hair dryer power on-
off slide switch are mounted shall have a
comparative tracking index (CTI) rating of 2 or
better, and a flammability rating of V-1 or better
N/A
18.1.6
Insulating tape shall comply with the Standard for
Polyvinyl Chloride, Polyethylene, and Rubber
Insulating Tape, UL 510.
N/A
18.1.7
Insulation sleeving shall comply with the Standard
for Coated Electrical Sleeving, UL 1441.
N/A
18.1.8
Insulation tubing shall comply with the Standard
for Extruded Insulating Tubing, UL 224
N/A
18.1.9
A printed-wiring board shall comply with the
requirements in the Standard for Printed- Wiring
Boards, UL 796. A printed-wiring board shall be
rated V-1 or better and shall comply with the
direct-support requirements for insulating materials
in the Standard for Polymeric Materials Use in
Electrical Equipment Evaluation, UL 746C
P
Exception: A printed-wiring board containing Class
2 non-safety circuit only is required to comply with
the Standard for Printed-Wiring Boards, UL 796
with flammability rating of HB or better
P
18.10
Unless otherwise specified, the flammability class
and temperature rating shall be that specified for
insulating materials in the Standard for Polymeric
Materials Use in Electrical Equipment
Evaluation, UL 746C
P
18.2
Film-coated wire (magnet wire)
N/A
18.2.1
The component requirements for film coated wire
and Class 105 (A) insulation systems are not
specified
N/A
18.2.2
Film coated wire in intimate combination with one
or more insulators, or the magnet wire of induction
heating coil, incorporated with an insulation
system rated Class 120 (E) or higher, shall comply
with the magnet wire requirements in the Standard
for Systems of Insulating Materials General, UL
1446 and shall have a suitable temperature class
N/A
19
Thermal Insulation
P
19.1
Combustible thermal and electrically conductive
insulation shall not contact an uninsulated live
part.
P
19.2
Mineral wool thermal insulation that contains
conductive impurities in the form of slag shall not
come into contact with any uninsulated live part
N/A
19.3
Thermal insulation shall be rated for the
temperature to which it is exposed when tested
under the conditions described in 44.1.1
N/A
20
Overcurrent Protection
P