Third Party Verification Claim

Page 25 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
Exception: Other sizes of quick-connect terminals
shall be investigated with respect to crimp pull out,
insertion-withdrawal, temperature rise, and all
tests shall be conducted in accordance with UL
310
N/A
16.18
Wire connectors shall comply with the Standard for
Wire Connectors, UL 486A-486B.
N/A
16.19
Splicing wire connectors shall comply with the
Standard for Splicing Wire Connectors, UL 486C
N/A
16.20
Single and multipole connectors for use in data,
signal, control and power applications within and
between electrical equipment, and that
are intended for factory assembly to copper or
copper alloy conductors, or for factory assembly to
printed wiring boards, shall comply with the
Standard for Component Connectors for Use in
Data, Signal, Control and Power Applications, UL
1977
N/A
16.21
Multi-pole splicing wire connectors that are
intended to facilitate the connection of hard- wired
utilization equipment to the branch- circuit
conductors of buildings shall comply with the
Standard for Insulated Multi-Pole Splicing Wire
Connectors, UL 2459.
N/A
16.22
Equipment wiring terminals for use with all alloys
of copper, aluminum, or copper-clad aluminum
conductors, shall comply with the Standard for
Equipment Wiring Terminals for Use with
Aluminum and/or Copper Conductors, UL 486E
N/A
16.23
Terminal blocks shall comply with the Standard for
Terminal Blocks, UL 1059, and, if applicable, be
suitably rated for field wiring
N/A
Exception: A fabricated part performing the
function of a terminal block need not comply with
UL 1059 if the part complies with the requirements
of
N/A
Pin terminals, Section 13.3.2
N/A
Live Parts, Section 14
N/A
17
Heating Element
P
17.1
A heating element shall be supported in a reliable
manner and shall be protected against mechanical
damage and contact with outside objects.
P
17.2
In determining whether a heating element is
reliably supported, consideration is to be given to
sagging, loosening, and other adverse conditions
resulting from continuous heating
P
17.3
An appliance in which the heating element is
designed for operation only in an air stream shall
be wired or controlled so that the element is
capable of operation only when under the cooling
effect of the air stream
N/A