Third Party Verification Claim

Page 24 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
16.11
A wire-binding screw or nut shall be provided with
a lock-washer if loosening by vibration permits
shifting of parts thereby reducing spacings, or
otherwise results in a risk of fire, electric shock, or
injury to persons. The lock- washer shall be
located under the head of a wire-binding screw or
under a wire-binding nut
N/A
16.12
An open-end spade lug shall not be used unless
additional means (such as upturned ends on the
tangs of the lug) are provided to hold the lug in
place if the wire-binding screw or nut becomes
slightly loosened
N/A
16.13
The means of connecting stranded internal wiring
to a wire-binding screw shall be such that loose
strands of wire are prevented from contacting
other live parts not always of the same polarity as
the wire and from contacting dead-metal parts.
This can be accomplished by using a pressure
terminal connector, a soldering lug, a crimped
eyelet, or by soldering all strands of the wire
together or the equivalent
N/A
16.14
A splice shall be provided with insulation
equivalent to that of the wires involved if spacing
between the splice and other metal parts is not
permanently maintained.
N/A
16.15
Insulation consisting of two layers of friction tape,
two layers of thermoplastic tape, or one
layer of friction tape on top of one layer of rubber
tape is acceptable on a splice. In determining
whether splice insulation consisting of coated
fabric, thermoplastic, or other type of tubing is
acceptable, consideration is to be given to such
factors as dielectric properties, heat- and moisture-
resistant characteristics, and similar criteria.
Thermoplastic tape wrapped over a sharp edge
shall not be used
N/A
16.16
Quick-connect type wire connectors shall be
suitable for the wire size, type (solid or stranded),
conductor material (copper or aluminum) and the
number of conductors terminated. If insulated, they
shall be rated for the voltage and temperature of
the intended use. They shall be applied per the
installation instructions of the wire connector
manufacturer
N/A
16.17
Quick-connect terminals, both connectors and
tabs, for use with one or two 22 10 AWG copper
conductors, having nominal widths of 2.8, 3.2, 4.8,
5.2, and 6.3 mm (0.110, 0.125, 0.187,
0.205, and 0.250 inch), intended for internal wiring
connections in appliances, or for the field
termination of conductors to the appliance, shall
comply with the Standard for Electrical Quick-
Connect Terminals, UL 310
N/A