Third Party Verification Claim

Page 22 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
Exception: An appliance that renders the adjacent
receptacle completely unusable is acceptable.
N/A
13.6.5
An appliance shall not be provided with a
mounting tab unless all the following conditions
are met
N/A
The appliance is of a type such that
semipermanent mounting will not introduce a risk
of fire or electric shock
N/A
The appliance is intended for use on a 15-
ampere, 125-volt receptacle
N/A
13.6.6
The enclosure of a direct plug-in appliance shall
be capable of being gripped for removal from the
receptacle to which it is connected, and the
perimeter of the face section from which the
blades project shall be no less than 5/16 inch (7.9
mm) from any point on either blade
N/A
Exception: For tab-mounted appliances intended
for use with fixed systems, the perimeter of the
face section shall not be less than 1/4 inch (6.4
mm) from any point on either blade
N/A
14
Live Parts
P
14.1
A current-carrying part shall be of silver, copper, a
copper alloy, or equivalent material
P
14.2
Plated iron or steel may be used for a current-
carrying part
P
Whose temperature during intended operation is
more than 100°C (212°F);
P
If provided in a component in accordance with 2.1;
but unplated iron or steel shall not be used
N/A
Exception: Stainless steel and other corrosion-
resistant alloys may be used for current- carrying
parts regardless of temperature
N/A
14.3
An uninsulated live part shall be secured to the
base or mounting surface so that it will be
prevented from turning or shifting in position if
such motion results in a reduction of spacings
below the minimum required values
P
14.4
Friction between surfaces shall not be used as a
means to prevent shifting or turning of an
uninsulated live part, but a lock washer applied as
intended is acceptable.
N/A
15
Reservoirs
N/A
15.1
If a reservoir is part of an appliance, a live part
shall be located or protected so that it will not be
subject to dripping if the reservoir does not
perform as intended
N/A
Exception: The requirement need not apply if the
reservoir is resistant to corrosion from the liquid
intended for use in it, and the reservoir does not
develop cracks as a result of aging.
N/A
16
Internal Wiring
P
16.1
The wiring and connections between parts of an
appliance shall be protected or enclosed
P