Third Party Verification Claim
Page 21 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
13.5.5
A separate soft rubber, neoprene, or polyvinyl
chloride bushing may be used in the frame of a
motor or in the enclosure of a capacitor physically
attached to a motor (but not elsewhere in an
appliance) when
N/A
The bushing is not less than 1/16 inch (1.6 mm)
thick, with a minus tolerance of 1/64 inch (0.4
mm); and
N/A
The bushing is located so that it will not be
exposed to oil, grease, oily vapor, or other
substance having a harmful effect on the bushing
material
N/A
Exception: A bushing of any of the materials
specified may be used at any point in an appliance
if used in conjunction with a type of cord for which
an insulating bushing is not required and if the
edges of the hole in which the bushing is mounted
are smooth and free from any burr, fin, or similar
abrading surface.
N/A
13.5.6
An insulated metal grommet may be used in place
of an insulating bushing if the insulating material
used is not less than 1/32 inch (0.8 mm) thick and
completely fills the space between the grommet
and the metal in which it is mounted
N/A
13.6
Direct plug-in appliances
N/A
13.6.1
With regard to Figure 13.4, the maximum moment,
center of gravity, dimensions, and weight of a
direct plug-in appliance shall comply with the
requirements specified in (a) – (d). See
13.6.2 and 13.6.3 for symbol definitions and
methods of application
N/A
The quotient of WY/Z shall not exceed 48 ounces
(1.36 kg).
N/A
The quotient of WY/S shall not exceed 48 ounces
N/A
13.6.2
Definitions for the symbols used in 13.6.1 are as
follows
N/A
W is the weight of the appliance
N/A
Y is the distance illustrated in Figure 13.4
N/A
13.6.3
The moment and weight specified in 13.6.1 are to
be determined as follows for
N/A
An appliance with an attached cord, the cord is to
be cut off at the enclosure or at the strain- relief
means if the strain-relief means extends outside
the enclosure
N/A
An appliance with a directly mounted accessory,
the values are to be measured with the accessory
in place
N/A
13.6.4
When inserted in a parallel-blade duplex
receptacle, any part of an appliance, including a
mounting tab, shall not interfere with full insertion
of an attachment plug into the adjacent
receptacle as illustrated in Figure 13.5.
N/A