Third Party Verification Claim
Page 17 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
13.3.1.10
When a 3-wire grounding-type attachment plug or
a 2-wire polarized attachment plug is provided, the
attachment plug connections shall comply with
Figure 13.2 and the polarity identification of the
flexible cord shall comply with Table 13.3
N/A
13.3.1.11
Type SPT-2, SVT, or SVTO flexible cord may be
used for connecting a pendant-type on-off switch,
a temperature control, or both to a table- or floor-
supported hair dryer
N/A
13.3.1.12
A power supply cord shall not employ conductors
smaller than 18 AWG (0.82 mm2).
P
Exception: Hand-supported household appliances
weighing less than 1/2 pound (0.23 kg), including
facial saunas, curling irons and brushes, manicure
and pedicure sets, hair crimping and hair
straightening irons, may employ non-detachable
power-supply cords with 20 AWG (0.52 mm2)
conductors provided that
P
The flexible cord is type SPT-1, SP-1, SPE-1 or is
a type that is, at minimum, equivalent to these
types
P
The appliance is not intended for continuous use
nor for being indefinitely left on in stand-by mode
(initial warm-up period excluded)
P
13.3.1.13
A power supply cord with integral fittings shall
comply with the requirements in the Standard for
Cord Sets and Power-Supply Cords, UL 817,
except that it is not required to be provided with
integral overcurrent protection
P
Exception: A power supply with integral swivel
assembly shall comply with the applicable
requirements in this standard and the following
requirements in the Standard for Cord Sets and
Power-Supply Cords, UL 817:
P
Normal Temperature Test, Section 87, with the
temperature rise at swivel contact not more than
30°C
P
Accelerated Aging Tests, Section 90
N/A
13.3.1.14
Hand-supported appliances provided with
detachable power supply cords, including hand-
supported appliances likely to be
disconnected while under load, shall not pose a
risk of electric shock, fire or injury when mated or
disconnected under any orientation or polarity
permitted by the construction. The mating
connector shall be held securely in place and shall
not be allowed to rotate.
Compliance is determined by the test of 65.4 and
65.5.
N/A