Third Party Verification Claim

Page 15 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
13.2.12
The surface of an insulated lead intended solely
for the connection of an equipment- grounding
conductor shall be green, with or without one or
more yellow stripes, and no other lead shall be so
identified
N/A
13.2.13
A wire-binding screw intended for the connection
of an equipment grounding conductor shall have a
green colored head that is hexagonal shaped,
slotted, or both. A pressure wire connector shall be
plainly identified as such by being marked
G, GR, GND, Grounding, or
the like or by a marking on the wiring
diagram provided on the appliance. The wire-
binding screw or pressure wire connector shall be
located so that it is unlikely to be removed during
servicing of the appliance.
N/A
13.2.14
A terminal solely for connection of an equipment
grounding conductor shall be capable of securing
a conductor of the correct size for that purpose.
N/A
13.3
Cord-connected appliances
P
13.3.1
Cords and plugs
P
13.3.1.1
An appliance shall be provided with a length of
flexible cord in accordance with Table 13.1 and an
attachment plug for connection to the supply
circuit. A coiled cord shall not be used with a floor-
or counter-supported appliance where such use
would present a risk of burn, fire, electric shock, or
injury to persons (for example, the appliance being
pulled off a table by the force of the cord). The
cord length is measured from the point of cord
entry into the enclosure, or into the wiring device
at the appliance end of the cord, to the face of the
attachment plug. The length for a coiled cord is to
be measured with the cord in an uncoiled position
P
Exception: When a power supply cord contains a
right-angle attachment plug, the cord length shall
be measured from the point of cord entry into the
enclosure, or into the wiring device at the
appliance end of the cord, to the edge of the line
blades or grounding pin nearest the point of cord
entry into the attachment plug as shown in Figure
13.1.
P
13.3.1.2
The flexible cord
UL cord used
P
May be permanently attached to the appliance or
For other than a hand-supported appliance, may
be in the form of a detachable power supply cord
with means for connection to the appliance
P
Examples of the means for connection are an
appliance plug, a flatiron plug, or a cord connector
cooperating with pin or blade terminals on the
appliance
N/A