Third Party Verification Claim

Page 14 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
Exception: A No. 8 (4.2 mm) screw may be used
at a terminal intended only for the connection of a
14 AWG (2.1 mm2) conductor, and a No. 6 (3.5
mm) screw may be used for the connection of a 16
AWG (1.3 mm2) or 18 AWG (0.82 mm2) control-
circuit conductor
N/A
13.2.6
A terminal plate tapped for a wire-binding screw
shall be of metal not less than 0.050 inch (1.27
mm) thick. There shall be two or more full threads
in the metal, which may be extruded if necessary
to provide the threads
N/A
Exception: A plate less than 0.050 inch thick, but
not less than 0.030 inch (0.762 mm) thick, is
acceptable if the tapped threads are determined to
have equivalent mechanical strength
N/A
13.2.7
Upturned lugs or a cupped washer shall be
capable of retaining a conductor of the size
specified in 13.2.1, but not smaller than 14 AWG
(2.1 mm2), under the head of the screw or the
washer
N/A
13.2.8
A wire-binding screw shall thread into metal.
N/A
13.2.9
An appliance intended for connection to a
grounded power supply conductor and using a:
N/A
Lampholder or element holder of the Edison screw
shell type,
N/A
shall have one terminal or lead intended for
connection of the grounded conductor of the
supply circuit. The terminal or lead intended for
grounded connection shall be the one that is
connected to the screw shell of a lampholder or
element holder and that has no connection to a
single pole switch or single pole automatic control
N/A
Exception: With regard to connection of a single
pole automatic control, the requirements specified
in 24.1 shall apply
N/A
13.2.10
A terminal intended for the connection of a
grounded circuit conductor shall be made of, or
plated with, a metal substantially white in color and
shall be readily distinguishable from the other
terminals. If not of such metal, the identification of
that terminal shall be clearly shown in some other
manner, such as on an attached wiring diagram. A
lead intended for the connection of a grounded
circuit conductor shall be finished to show a white
or gray color and shall be readily distinguishable
from the other leads
N/A
13.2.11
The free length of a lead inside an outlet box or
wiring compartment shall be 6 inches (152.4 mm)
or more if the lead is intended for field connection
to an external circuit
N/A
Exception: A lead may be less than 6 inches long
if it is evident that the use of a longer lead will
result in a risk of fire, electric shock, or injury to
persons.
N/A