Third Party Verification Claim
Page 13 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
Exception: If an appliance is not intended for
permanent connection to a power supply, but is
intended to be either fastened in place, located in
a dedicated space, or both, it may be provided
with a short length of flexible cord in accordance
with 13.3.1.1 – 13.3.1.3 and 13.3.1.6 and with an
attachment plug forsupply connection. The
investigation of such a feature will include
consideration of the utility of the appliance and the
reasons for having it detachable from its supply
source by means of the attachment plug
N/A
13.1.2
The location of a terminal box or compartment in
which a power supply connection to a
permanently-connected appliance is to be made
shall be such that the connection may be readily
inspected after the appliance is installed as
intended.
N/A
13.1.3
A terminal compartment intended for the
connection of a supply raceway shall be attached
to the appliance so as to be prevented from
turning
N/A
13.2
Wiring terminals
N/A
13.2.1
An appliance intended for permanent connection
to the power supply shall be provided with wiring
terminals or leads for connection of supply circuit
conductors. Such wiring terminals or leads shall
accommodate conductors having an ampacity of
not less than 125 percent of the appliance current
rating when the load is continuous (3 hours or
more), and not less than the appliance current
rating when the load is intermittent
N/A
13.2.2
For the purpose of these requirements, wiring
terminals are considered to be terminals to which
power supply or control connections will be made
in the field when the appliance is installed
N/A
13.2.3
A wiring terminal shall be provided with a soldering
lug or with a pressure terminal connector securely
fastened in place (for example, firmly bolted or
held by a screw)
N/A
Exception: A wire-binding screw may be used at a
wiring terminal intended to accommodate a 10
AWG (5.3 mm2) or smaller conductor if upturned
lugs or the equivalent are provided to hold the wire
in position
N/A
13.2.4
A wiring terminal shall be prevented from turning
or shifting in position by means other than friction
between surfaces. This may be accomplished by
two screws or rivets; by square shoulders or
mortices; by a dowel pin, lug, or offset; by a
connecting strap or clip fitted into an adjacent part;
or by an equivalent means
N/A
13.2.5
A wire-binding screw at a wiring terminal shall be
no smaller than No. 10 (4.8 mm)
N/A