Third Party Verification Claim
Page 122 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
TABLE: Normal Temperature Test
P
Test voltage (V) .....................................................:
120
⎯
Ambient (C) ......................................................... :
23.3
⎯
Thermocouple locations
Max. temperature rise measured,
T (K)
Max.temperature rise limit,
T (K)
Power supply cord
34.5
80
Handle
29.2
50
Enclosure near heater, internal
94.5
Ref.
Internal wire
54.1
100
PCB
35.8
130
Power switch
19.2
70
Test corner
16.0
65
Supplementary information:
TABLE: Leakage current
P
Test voltage (V) ................................................ ...:
120
⎯
Leakage current between
I (mA)
Max. allowed I (mA)
L/N of the supply to enclosure
0.01
0,35 mA peak
Supplementary information: N/A
TABLE: Electric strength
P
Test voltage applied between:
Voltage (V)
Breakdown
(Yes/No)
L/N of the supply to enclosure
3000
No
Supplementary information: