Third Party Verification Claim

Page 121 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
89.1
A wall unit or a hanging bracket shall be
permanently marked where readily visible during
installation in letters having a contrasting color to
the background with the word DANGER and the
following or the equivalent: To reduce risk of death
by electric shock, do not install where unit can fall
into a tub or sink. The height of the letters in the
word DANGER shall be no less than 1/8 inch (3.2
mm), and the height of the remaining letters shall
not be less than 1/16 inch (1.6 mm). Block
lettering shall be used for all words
N/A
Exception: The marking is not required to be in
contrasting colors if the letters are embossed or
indented to a depth of not less than 0.020 inch
(0.5 mm)
N/A
89.2
A warning tag that is in compliance with 72.4.2
72.4.4 shall be provided; however, use of following
items are optional:
N/A
Always unplug it after use. See 72.4.2(a)
N/A
The heading unplug it. See Figure 72.1.
N/A
90
Use and Care Instructions
P
90.1
Warning instructions in compliance with
Instructions Pertaining to a Risk of Fire, Electric
Shock, or Injury to Persons, Section 74, shall be
provided, with the following modifications:
P
Item 1 under DANGER of Important Safety
Instructions (see 74.6) shall be replaced with Do
not install unit where it can fall into a tub or sink.
Always return hand unit to wall unit after using.
P
Item 1 under WARNING of Important Safety
Instructions (see 74.6) need not be provided
P
91
Installation Instructions
P
91.1
Installation instructions for hanging of the wall unit
as intended shall be packaged with a wall- hung
hair dryer. The instructions shall include a list of
the items provided (such as screws, anchors,
brackets, and similar hardware); the tools needed;
and the step-by-step instructions for preparation of
mounting surface, application of the hanging
hardware, method of hanging the wall unit, and the
like
P
91.2
The installation instructions shall include the
warning specified in 89.1, preceding the detailed
instructions specified in 91.1
P