Third Party Verification Claim
Page 120 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
86
General
P
86.1
The appliance shall comply with the applicable
requirements specified in Sections 2 – 77 and with
the requirements specified in Sections 87 –
91. The hand unit shall comply with the applicable
requirements for a hand-supported hair dryer. If
there is a discrepancy between the requirements
in Sections 87 – 91 and those in Sections 2 – 77,
the requirements in Sections 87 – 91 shall apply
P
87
Construction
P
87.1
The appliance shall be provided with all the
hardware necessary for hanging the wall unit in
accordance with the installation instructions. The
construction shall be such that the appliance
withstands the force as described in
59.1 without damage to the supporting surface, to
the hanging means, or to the appliance that results
in the risk of electric shock, fire, or injury to
persons
P
87.2
The wall unit shall engage the hanging means
on the wall. Dismounting the wall unit from the
hanging means shall not require the use of a tool
but shall require a positive and deliberate action by
the user
N/A
87.3
The appliance shall be constructed so that the
hand unit cannot be energized while stored in the
wall unit as intended
P
87.4
The switch provided in accordance with 23.1.1
shall be in the wall unit, in the hand unit, or in both
the wall unit and the hand unit. The switch shall be
located so that it is readily accessible to the user
to turn off the unit
P
87.5
A GFCI or other immersion protective device shall
be integral with the attachment plug of the wall-
hung hair-drying appliance power supply cord
N/A
Exception: Immersion protection shall comply with
the requirements in Exception No. 2 of 7.5.
N/A
88
Performance
N/A
88.1
As part of the investigation, a wall-hung hair dryer
shall be trial-installed to determine that the
installation is feasible and that the instructions are
detailed and correct
N/A
88.2
The appliance shall comply with the Immersion
Protection Trip Time Measurement Test, Section
40. The hand unit and wall unit shall be immersed
simultaneously and the hand unit shall be off its
holder. Power switches shall be tested in both the
on position and the off position
N/A
Exception No. 1: A wall-hung hair dryer protected
by a GFCI need not be subjected to this test
N/A
89
Markings
N/A