Third Party Verification Claim

Page 12 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
Exception: The test need not be conducted on a
construction for which there is no possibility of
molten wax spilling from its container under any
condition of use, such as constructions in which
the wax material is contained within completely
enclosed wax applicators.
N/A
12
Hanging and Mounting Means
N/A
12.1
A wall-hung or a wall-mounted appliance shall
withstand a force as described in 59.1 without
evidence of damage to the mounting surface, to
the hanging means, to the mounting means, or to
the appliance that results in the risk of electric
shock, fire, or injury to persons.
N/A
12.2
A cord-connected appliance that is provided with
keyhole slots, notches, hanger holes, or similar
feature, for hanging the appliance on a wall, shall
be
N/A
Provided with the necessary hardware for hanging
the appliance in accordance with the installation
instructions and
N/A
Constructed in such a manner that the hanging
means (such as screws) shall not be accessible
without removing the appliance from the
supporting means
N/A
12.3
When determining compliance with 12.2, any part
of the enclosure or barriers that can be removed
without the use of tools to gain access to the
hanging means is to be removed
N/A
12.4
A keyhole slot, notch, or hanger hole shall be
located so that the supporting screws or similar
hardware cannot damage any electrical insulation
or reduce spacings to current- carrying parts of
the appliance
N/A
12.5
A permanently installed wall-mounted appliance
shall be provided with the necessary hardware for
mounting in accordance with the installation
instructions
N/A
Exception: Small parts commonly available for the
mounting of the appliance need not be provided if
the installation instructions refer to such parts as
specified in 75.4
N/A
13
Supply Connections
P
13.1
Permanently-connected appliances
N/A
13.1.1
An appliance intended for permanent connection
to a power supply, either by being fastened in
place, located in a dedicated space, or both,
shall have provision for connection of one of the
wiring systems that is acceptable for the appliance
N/A