Third Party Verification Claim
Page 118 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
The supply circuit voltage is to be adjusted to the
test voltage as specified in 44.1.13.
N/A
Exception: The voltage is not to be increased to
cause rated wattage input. The leakage current
measurements are to be taken with the electrolyte
in the heated condition producing maximum
leakage, using the measurement circuit described
in 38.5
N/A
82
Disassembly and Reassembly
P
82.1
If the instructions involve disassembly of any parts
for cleaning, it shall be determined that the
appliance is unlikely to be reassembled in a
manner that will result in a risk of fire, electric
shock, or injury to persons
P
83
Markings
P
83.1
The appliance shall be marked with the following
P
A fill-level marking that can easily be compared
with the actual water level during filling, or
instructions for the use of any integral measuring
container or other measuring means for filling. If
the measuring container is not integral with the
appliance, the amount shall be expressed in
standard measurements in addition to the use of
any measure provided
P
The word CAUTION and the following or the
equivalent: Shock hazard. To provide continued
protection against electric shock
N/A
83.2
An electrode-type appliance having a water
reservoir or boiling chamber with a capacity of 8
ounces (23.7 mL) or less shall be marked with the
word CAUTION and the following or the
equivalent: To reduce the risk of excessive water
temperatures that may cause burns if the unit is
upset, follow manufacturer’s instructions on filling,
cleaning, and rinsing. The height of the letters in
the word CAUTION shall not be less than 1/8 inch
(3.2 mm), and the height of the remaining letters
shall not be less than 7/64 inch (2.8 mm). For an
electrode-type appliance, this marking shall be in
addition to the marking specified in 83.1
N/A
Exception: The additional marking is not required
on an electrode-type appliance that, does
not release more than 2 ounces (5.9 mL) of water
when filled with water in accordance with the
manufacturer’s instructions and placed on a 30-
degree inclined plane and in the position
determined most likely to result in water spillage or
overflow. For purposes of this test, the appliance
may be restrained on the inclined plane to avoid
tip over
N/A