Third Party Verification Claim
Page 117 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
80.4
Three samples are to be subjected to the test
indicated in 80.2
N/A
Exception: The test solution is to be 3 grams of
sodium chloride per liter of distilled water
N/A
81
Leakage Current Test
N/A
81.1
An electrode-type appliance shall be constructed
so that, with the appliance assembled for use in its
intended manner, there are no openings in the
enclosure or guard permitting contact with the
energized water by a copper alloy rod sized as
N/A
Illustrated in Figure 81.1 and
N/A
Determined in 8.5.3 – 8.5.5
N/A
81.2
The leakage current available from accessible
surfaces (including those moistened by the liquid)
under any condition of intended operation shall not
be greater than 0.5 milliampere when the unit is
operated with a hard water solution consisting of
1/2 gram of calcium sulfate, CaSO4 2H2O, per
liter of distilled water
N/A
81.3
During the determination specified in 81.1, 81.2,
and 81.4, a barrier or enclosure whose
acceptability for the particular application has not
been determined is to be removed
N/A
81.4
The leakage current, measured under the
following conditions (a) and (b), shall not be
greater than1.5 milliampere
N/A
A sample at room temperature is to be filled with a
volume of hard water solution (made as specified
in 81.2) equal to 150 percent of the maximum
recommended amount. The leakage to ground is
to be made with the unit operating while tipped in
any direction and at any angle not exceeding 30
degrees to cause maximum leakage current. The
probe used in the measurements is to be a copper
alloy rod with an insulating handle. The rod is to be
sized as illustrated in Figure 81.1
N/A
The test in (a) is to be repeated with the appliance
mounted on a horizontal surface with 200 percent
of the maximum recommended volume of hard
water solution
N/A
Exception: If the appliance is provided with a
polarized attachment plug, the leakage current
shall be no greater than 0.5 milliampere with the
plug inserted in the receptacle in the intended
position and shall be no greater than 5.0
milliamperes with the polarity reversed.
N/A
81.5
During the tests outlined in 81.2 – 81.4:
N/A
The appliance is to be energized with the
attachment plug (including a polarized plug)
inserted in one position into a receptacle
connected to a grounded supply circuit and then
with the polarity reversed and
N/A