Third Party Verification Claim
Page 116 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
79.2
The interposed barrier assembly may consist of
two or more layers arranged to provide a baffle
effect for all openings
N/A
80
Operation Test
P
80.1
An electrode-type facial steamer, when subjected
to the operation test specified in 80.2, shall be
such that
P
There is neither appreciable distortion nor any
cracking of any of its parts,
P
There is no evidence of arcing or tracking over the
surface or through insulating material
N/A
80.2
Three samples completely assembled as for
intended use are to be subjected to the following
test. A test solution of 4 grams of sodium chloride
(NaCl) per liter of distilled water is to be
prepared. The electrode portion of the appliance is
to be connected to a 150-volt alternating-current
supply through a 20-ampere time-delay fuse and
filled to the recommended fill level from a
nonconducting container with the test solution.
After the current in the electrode portion has
reduced to an average value of less than 20
percent of rated current of the electrode portion,
the unit is to remain connected to the supply for an
additional 10 minutes. Without emptying or
cleaning, the unit is then to be filled to the fill level
with distilled, deionized, or tap water having a
resistivity greater than 20,000 ohm-centimeters.
The cycling is to be continued for a total of 30
complete cycles. After the thirtieth cycle, the unit
is to be de- energized and filled with tap water and
then emptied. The preceding steps are to be
repeated nine times starting with the filling using
the saline test solution to obtain 300 cycles of
operation. In cases where there is loss of
solution salt, sufficient sodium chloride is to be
added to the distilled, de- ionized, or tap
water to prevent the operating portion of a
cycle from exceeding 200 percent of the time
consumed by the initial operating cycle. If the fuse
blows at any time during the test, the appliance
is to be emptied, filled with tap water, allowed to
stand for 5 seconds, and emptied. The unit is then
to be filled with the test solution, and the test
continued. In each filling care should be taken to
fill only to the manufacturer’s recommended fill
level and not to overfill the samples
N/A
80.3
An electrode-type appliance other than specified in
80.1, when subjected to the operation test
specified in 80.4, shall be such that:
N/A
There is neither appreciable distortion nor any
cracking of any of its parts
N/A
There is not evidence of arcing or tracking over the
surface or through insulating material
N/A