Third Party Verification Claim

Page 11 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
10.3
Friction alone shall not be relied on for turn-
prevention as required in 10.2. A lock-washer,
applied as intended, is a reliable means of turn-
prevention of a device with a single-hole mounting
means
N/A
10.4
A positive means shall be provided to prevent
parts of an appliance from turning with respect to
each other if such turning would result in reduction
of spacings, twisting of wires, and the like
N/A
Exception: If such parts depend upon 3/8 inch (9.5
mm) or larger pipe threads, no additional means to
prevent turning need be provided
N/A
10.5
A fastener that secures the insulating tip of a
curling iron, a heated brush, or a similar appliance
shall be constructed, fastened, or located so as to
prevent the fastener from becoming loosened if
such loosening can result in a risk of fire or electric
shock.
P
10.6
Compliance with the requirement specified in
10.5 may be accomplished by use of
P
10.7
If any part of a metal spring of a hair clamp of a
curling iron or a similar appliance can become
loose inside the enclosure of electrical parts as a
result of breakage of the spring, the construction
shall be such that electrical spacings will not be
reduced
N/A
10.8
Compliance with the requirement specified in
10.7 may be accomplished by
N/A
Locating all parts of the spring outside the
enclosure of electrical parts
N/A
Using barriers
N/A
10.9
The temperature sensor of a temperature
controller, a thermostat, a thermal cutoff, or a
similar device shall be secured in place
N/A
11
Stability
N/A
11.1
A floor- or counter-supported appliance shall be
constructed such that it will not be overturned
when tested in accordance with 37.1
N/A
Exception: An appliance whose overturning during
intended use will not present a risk of burns or
injury to persons need not be tested
N/A
11.2
With regard to 11.1, a hand-supported hair dryer
provided with a stand for conversion into a
counter-supported hair dryer is to be evaluated as
a hand-supported appliance and is not to be
subjected to the stability test.
N/A
11.3
A wax depilatory appliance shall be tested and the
results shall be evaluated as described in 37.2,
except that the wax may be in any combination of
solid and liquid states anticipated during the
intended operation of the appliance. Any movable
parts or covers are to be in the positions that result
in the most adverse conditions of use
N/A