Third Party Verification Claim

Page 100 of 129 Report No.: JAT2209271146SR-1
UL 859
Clause
Requirement + Test
Result - Remark
Verdict
Room 303, Building 1, No.316, Renzhou Road, Shatian Town, Dongguan City, Guangdong Province, China.
Tel: 0769-81710286 E-mail: wangzhao@junantest.com Website: www.junantest.com
71.1
An appliance shall be rated in volts and amperes
or watts. It may be rated for alternating current
only or direct current only. The rating shall include
the number of phases if the appliance is for use
on a polyphase circuit and the frequency, if
needed to comply with requirements in this
standard, for a motor relay coil or other
component. To determine compliance, the
requirements in 43.3 shall be used. For a preheat
type appliance, the ampere or wattage rating shall
be based on the maximum value measured during
the preheat cycle
P
71.2
The current rating of an appliance shall include 15
amperes for a single receptacle provided as part of
the appliance and intended as a general use
outlet, 20 amperes for two or more receptacles
(including a single duplex receptacle), or, if the
outlet is marked as noted in 72.1.6, that marked
rating shall be included in the current rating of the
appliance
P
71.3
The voltage rating of a cord-connected appliance
intended for connection to a nominal 120-volt
supply circuit shall not exceed 125 volts. The
voltage rating of a dual-voltage appliance intended
for connection to a nominal 120/240 volt supply
circuit shall not exceed 125/250 volts.
N/A
72
Details
P
72.1
General
P
72.1.1
An appliance shall be legibly and permanently
marked, where it will be plainly visible (after
installation in the case of a permanently connected
appliance), with
P
The manufacturers name, trade name, trademark,
or other descriptive marking by which the
organization responsible for the product is
identified;
P
The date or other dating period of manufacture not
exceeding any three consecutive months, which
may be abbreviated or in a nationally recognized
code, or in a code affirmed by the manufacturer;
P
Exception No. 1: The date of manufacture may be
located where visible behind a cover that is
movable without the use of a tool. If the cover is
removable, the marking shall be on other than the
cover
N/A
72.1.2
The repetition time cycle of a date code shall not
be less than 10. The date code shall not require
reference to the manufacturers records to
determine when the appliance was manufactured
P