➢ Place the Sill CST 998 on the curb centerline with weep holes to the inside of
the enclosure. Push the Sill against the wall under the Wall Jamb CST 956.
➢ OPTIONAL: Secure Sill to curb with Screws.
➢ Drill 3/16” holes through the Sill at (3) pre-drilled 3/8” holes in the Sill.
➢ Drill 3/16” holes 1-1/2” deep into the curb at the (3) pre-drilled holes in the Sill.
➢ Insert Plastic Screw Anchors 1329 into the holes.
➢ Secure the Sill using (3) Installation Screws 6-8114PHP (#8 x 1-1/14”).
STEP 6. SET PANEL AND INSTALL COVER AND SILL CAP
➢ Set the Panel into the Sill CST 998 and push it onto the
Wall Jamb CST 956. The metal grid is to the outside.
➢ Attach the Panel Snap Cover CST 952 to the exposed
vertical edge of the Panel using a rubber mallet.
➢ Adjust the Panel onto / off the Jamb until the Snap Cover
is flush with the end of the Sill.
➢ Insert the Sill End Cap CP967B into the end of the Sill.
CST 952
CP967B
CST 998
PANEL
CST 952
CST 998
CP967B
STEP 5. SET SILL AND * SECURE TO CURB (*OPTIONAL)
CST 998
6-8114PHP (3x)
6-8114PHP (3x)
CST 998
1329 (3x)
Outside Shower
Enclosure
WEEP HOLES
TO INSIDE
PANEL
FLUSH
CST 952
CST 956
3/8” HOLE (3x)
3/16” DRILL BIT