Instructions / Assembly

5
GRIDSCAPE FIXED PANEL
INSTALLATION INSTRUCTIONS FULL DIVIDED-LIGHT
1/8”
STEP 3. INSTALL WALL JAMB
Set the Wall Jamb CST 956 into the Sill CST 998 and up against the wall.
While holding the Jamb plumb with a level, use the pre-drilled holes in the
Jamb to pencil mark (5) hole locations on the wall.
Remove the Jamb and drill installation holes 1-1/2” deep using a 3/16”
masonry bit. Insert Plastic Screw Anchors 1329 into the holes.
Secure the Jamb in place using (5) Installation Screws 6-8114PHP (#6
Head - #8 x 1-1/14” Pan Head Philips).
CST 956
CST 998
STEP 4. SET PANEL AND TRIM SILL
Set the Panel into the Sill CST 998 and push it
onto the Wall Jamb CST 956 until the Panel is tight
against the Jamb. The metal grid is to the outside.
Mark the Sill at 1/8” from the end of the Panel (add
1/8” for the Snap Cover CST 952).
Set aside the Panel.
Trim the Sill to the mark / measurement.
PLUMB
CST 956
CST 998
6-8114PHP (5x)
1329 (5x)
PLUMB
CST 956
PANEL
Outside Shower
Enclosure
CST 956
CST 956
CST 998
PANEL
CST 998
PANEL
CST 956