Installation Guide

3
SAFETY
SWITCHES
Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog
Discount Schedule GDSS
General Duty Safety Switches
Selection
3-8
Siemens / Speedfax Previous folio: 3-8
Indoor — Type 1 Outdoor — Type 3R
Horsepower Ratings
240V AC
250
1-Phase, 2-Phase, 3-Phase, Volt
Ampere Catalog List Ship Wt.* Catalog List Ship Wt.*
2-Wire 4-Wire 3-Wire DC
System Rating Number Price $ Std. Pkg. Number Price $ Std. Pkg. Std. Max. Std. Max. Std. Max. Std.
030 GF221N 127.00 035
GF221NR
203.00 035
01
1
⁄2 03—— 03 007
1
⁄2 05
060 GF222N 217.00 014 GF222NR 334.00 014 0310 —— 07
1
⁄2 015 10
100 GF223N 437.00 023 GF223NR 492.00 024 07
1
⁄2 15 — — 15 030 20
200 GF224N 907.00 047 GF224NR 1287.00 048 15 — — — 25 060 40
400 GF225NH
2753.00 128 GF225NRH
3730.00 130 15 — — — 50 125 50
400 GF225N 2774.00 153 GF225NR 3752.00 157 15 — — — 50 125 50
600 GF226NH
5438.00 133 GF226NRH
6897.00 135 15 — — — 75 200 —
600 GF226N 5467.00 159 GF226NR 6929.00 159 15 — — — 75 200 —
030 GF321N 203.00 024
GF321NR
302.00 024
01
1
⁄2 03—— 03 007
1
⁄2 05
060 GF322N 334.00 015 GF322NR 454.00 015 0310 —— 07
1
⁄2 015 10
100 GF323N 581.00 025 GF323NR 840.00 025 07
1
⁄2 15 — — 15 030 20
200 GF324N 1287.00 049 GF324NR 1524.00 050 15 — — — 25 060 40
400 GF325NH
3262.00 136 GF325NRH
3934.00 138 15 — — — 50 125 50
400 GF325N 3287.00 158 GF325NR 3955.00 162 15 — — — 50 125 50
600 GF326NH
6091.00 138 GF326NRH
8171.00 141 15 — — — 75 200 —
600 GF326N 6124.00 161 GF326NR 8205.00 165 15 — — — 75 200 —
240 Volt Fusible
2-Pole, 2-Fuse, and Solid Neutral
240 Volt AC/250 Volt DC
3-Pole, 3-Fuse, and Solid Neutral
240 Volt AC/250 Volt DC
030 GNF321 166.00 024
GNF321R
302.00 024
—3——007
1
⁄2 — 05
060 GNF322 209.00 012 GNF322R 466.00 013 — 10 — — 015 — 10
100 GNF323 492.00 023 GNF323R 840.00 024 — 15 — — 030 — 20
200 GNF324 887.00 046 GNF324R 1505.00 047 — 15 — — 060 — 40
400 GNF325 2275.00 114 Use 600V Switch — HNF365R — 15 — — 125 — 50
600 GNF326 4350.00 116 Use 600V Switch — HNF366R — 15 — — 200 — —
240 Volt Non-Fusible
2-Pole or 3-Pole 240 Volt AC/250 Volt DC
* In pounds (lbs).
Dual horsepower ratings: Std.- applies when non-time
delay fuses are installed. Max.- applies when time-
delay fuses are installed.
These switches are UL-listed for application on
grounded B-phase systems.
Suitable for use on 3-phase motor loads.
Service entrance labeled.
Has provision for ECHA type hub.
5 switches per standard package.
10 switches per standard package.
Height reduced switch (45.25 rather than 56 inches in
height) for use with 500MCM or smaller conductors.
Sect_03_Speedfax2007 3/26/07 5:05 PM Page 3-8