Installation Guide

3
SAFETY
SWITCHES
Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog
Discount Schedule GDSS
General Duty Safety Switches
Selection
3-8
Siemens / Speedfax Previous folio: 3-8
Indoor — Type 1 Outdoor — Type 3R
Horsepower Ratings
240V AC
250
1-Phase, 2-Phase, 3-Phase, Volt
Ampere Catalog List Ship Wt.* Catalog List Ship Wt.*
2-Wire 4-Wire 3-Wire DC
System Rating Number Price $ Std. Pkg. Number Price $ Std. Pkg. Std. Max. Std. Max. Std. Max. Std.
030 GF221N 127.00 035
GF221NR
203.00 035
01
1
2 03—— 03 007
1
2 05
060 GF222N 217.00 014 GF222NR 334.00 014 0310 07
1
2 015 10
100 GF223N 437.00 023 GF223NR 492.00 024 07
1
2 15 15 030 20
200 GF224N 907.00 047 GF224NR 1287.00 048 15 25 060 40
400 GF225NH
2753.00 128 GF225NRH
3730.00 130 15 50 125 50
400 GF225N 2774.00 153 GF225NR 3752.00 157 15 50 125 50
600 GF226NH
5438.00 133 GF226NRH
6897.00 135 15 75 200
600 GF226N 5467.00 159 GF226NR 6929.00 159 15 75 200
030 GF321N 203.00 024
GF321NR
302.00 024
01
1
2 03—— 03 007
1
2 05
060 GF322N 334.00 015 GF322NR 454.00 015 0310 07
1
2 015 10
100 GF323N 581.00 025 GF323NR 840.00 025 07
1
2 15 15 030 20
200 GF324N 1287.00 049 GF324NR 1524.00 050 15 25 060 40
400 GF325NH
3262.00 136 GF325NRH
3934.00 138 15 50 125 50
400 GF325N 3287.00 158 GF325NR 3955.00 162 15 50 125 50
600 GF326NH
6091.00 138 GF326NRH
8171.00 141 15 75 200
600 GF326N 6124.00 161 GF326NR 8205.00 165 15 75 200
240 Volt Fusible
2-Pole, 2-Fuse, and Solid Neutral

240 Volt AC/250 Volt DC
3-Pole, 3-Fuse, and Solid Neutral
240 Volt AC/250 Volt DC
030 GNF321 166.00 024
GNF321R
302.00 024
—3007
1
2 05
060 GNF322 209.00 012 GNF322R 466.00 013 10 015 10
100 GNF323 492.00 023 GNF323R 840.00 024 15 030 20
200 GNF324 887.00 046 GNF324R 1505.00 047 15 060 40
400 GNF325 2275.00 114 Use 600V Switch — HNF365R 15 125 50
600 GNF326 4350.00 116 Use 600V Switch — HNF366R 15 200
240 Volt Non-Fusible

2-Pole or 3-Pole 240 Volt AC/250 Volt DC
* In pounds (lbs).
Dual horsepower ratings: Std.- applies when non-time
delay fuses are installed. Max.- applies when time-
delay fuses are installed.
These switches are UL-listed for application on
grounded B-phase systems.
Suitable for use on 3-phase motor loads.
Service entrance labeled.
Has provision for ECHA type hub.
5 switches per standard package.
10 switches per standard package.
Height reduced switch (45.25 rather than 56 inches in
height) for use with 500MCM or smaller conductors.
Sect_03_Speedfax2007 3/26/07 5:05 PM Page 3-8

Summary of content (1 pages)