Product Literature

SPECIFICATIONS
Operational
Lynx
®
Central:
- Mapping capabilities
- Remote hand-held operation
- Weather station integration
- Pump station integration
• Enhanced diagnostics:
- Communication
- Electrical shorts/opens
- Solenoid check
Installation
• Maximum number of wire paths:
- 4 per gateway
• Maximum number of gateways:
- 4 per system (Standard)
- 9 per system Lynx Smart Hub
• Maximum number of decoders
per wire path:
- 250
• Maximum stations per gateway:
- 1000 integrated (Standard)
- 1600 o fairway (Standard)
- 1000 Lynx Smart Hub
• Maximum stations per system:
- 4000 integrated (Standard)
- 6400 o fairway (Standard)
- 9000 Lynx Smart Hub
Electrical
• Input power:
- 88-264 V ac, 50/60 Hz
• Output Power:
- Output voltage: 40 V ac max
- Output power: 75 VA max
- Class 2, SELV
• ISP 2-wire modules are rated at 20
KV surge protection
• 2-Wire modules wiring: 14 awg
• Simultaneous stations per
output board:
- 100
• Maximum distance from
central to module
(using 14 gauge wire): 2.6 miles
• Maximum distance from
module to sprinkler
(using 14 gauge wire): 400 ft.
• Solenoids per output: 2
DCLS-P
• Stations per module: 1, 2 or 4
Temperature
• Operating Temperature: 32° F
to 140° F
• Storage temperature: -22° F
to 212° F
• No holding power required to
operate stations
• Decoder identification is a
unique 5-character address
• Standalone option (GDC200)
O Fairway Configuration
Integrated Configuration
Standard
Lynx
®
DEC-ISP-4 DEC-ISP-2 DEC-ISP-1
DEC-PCS-1600
Lynx Smart Hub
Lynx
®
DEC-RS-1000-MFIU-2011DR DEC-RSP-1000-DR
or
Specifying InformationGateway or Lynx Smart Hub
DEC-XXX-XXXX-XX
Type Configuration Cabinet Station Count
Communication
Type
DEC XXX X XXXX XX
DEC SA—Stand-alone
PCS—Central
RS—Lynx Smart
Hub
WM Metal
P—Green Plastic
Pedestal
B—Brown Plastic
Pedestal
TTan Plastic
Pedestal
200200 Stations
16001600 Stations,
Standard
1000—1000 Stations,
Lynx Smart Hub*
M—Wireline
DR—Radio
*Only available
for Lynx
Smart Hub
Example: A1000 station Lynx Smart Hub with green plastic pedestal
and radio communication would be specified as: DEC-RSP-1000-DR
Note: A blank after RS indicates the wall mount cabinet.
P, B, and T indicate green, brown, and tan plastic pedestals.
Specifying Information—2-Wire Modules
DEC-ISP-X
Type Configuration
DEC-ISP X
DEC-ISP—Module* 1—1-station 2—2-station
4—4-station
Example: A 2-station GDC Module would be specified as: DEC-ISP-2
*Refer to sprinkler pages for specifying information on Sprinkler 2-wire Modules