Manual

25
Diagnostics
e Diagnostics function of the remote gateway allows for easy system troubleshooting. Within this function, the user
can monitor the gateways internal voltages as well as check the rmware version.
Use the Input Dial
to navigate through the menus while in the Menu: eld.
Menu: Link Monitor is menu item allows you to monitor communication network trac.
Menu: System Monitor is menu item allows you to monitor all the gateways in the system.
Menu: Revision is menu item will display the gateway rmware version and creation date.
Menu: Power-Up Detect is menu item will display the number of detected stations, number of detected sensors. It
will also display the date and time of the last power-down (PD) and last power-up (PU). Press
the Down arrow
to scroll down the informations.
Menu: VA Monitor is menu item allows you to monitor the gateways amperage, voltages and temperature in
real-time. is allows you to troubleshoot the gateway’s internal circuit voltages.
Menu: Event Codes is menu item will display the gateways Event Code log. You can clear the log from this
option. Navigate to the Clear eld using the Down arrow
, select Yes using the Input
Dial
and press the Down arrow to activate.
Menu: Link Settings Use this menu item to view the gateways communication settings. Parameters can not be
edited here.
Motherboard Diagnostic Display
e Gateway motherboard features a 2-line, 16 character LCD display for quickly viewing for system diagnostic
information (see Figure 6, page 9). Use the left button below the LCD to scroll through the display lines and if needed, use
the right button the scroll through the available options.
Rev 2.02
03/28/2011
After power up, the screen will display boards rmware version.
D1 A=1.500
D2 = OFF
After the initial Revision screen, the display will show the real time current for both
daughter boards.
D1L1=0.123 A
D1L2=0.121 A
D2L1=0.224 A
D2L2=0.223 A
e display will also show the load currents by individual
wires of a two-wire communication line.
Rain sw =open
Pump pres=closed
e display will show the Rain and Pump Pressure sensor state and will be updated in real
time.
D1 DEC 32396
10 min Send...
e display will show the information contained in the message during transmission
execution. e information will only be displayed while the transmission is being executed.
e display will refresh if a dierent command is transmitted.
Display Contrast
Psh Opt to Adj
Scroll to this menu to adjust the display contrast. Press the right button below the LCD to
adjust.
No Alarms
Use the Alarms display to view fault information such as daughter board thermal alarms,
shorts, high current and wire load imbalances. You can clear the alarms by pressing and
holding the scroll (left) button for four seconds.
00:00:06:23:05
is is the time counter in Month:Days:Hours:Minutes:Seconds which starts upon power
up.
Flow=0.00 Hz
e display will show the real time pulse frequency of the ow sensor input.