Station Settings
Station Settings allows you to set parameters specic to each station.
Use the Up or Down Arrows to navigate through the menus.
Use the Left and Right Arrow Keys to advance to the next entry eld on the same menu line.
Use the Input Dial to select values when editing.
Command Function
DB1 or 2 Select the daughterboard.
S01 Select the station you want to edit in this eld. Choose from Station 01 through the gateway maximum
station count of 500 (per daughterboard).
Sched Today: Total scheduled station runtime for the current irrigation day.
Water Today: Total station runtime that has occurred for the current irrigation day.
Runtime resulting from a station that is manually activated via the output hardware switch will not
be captured.
Water Yestr: Total station runtime that occurred for the previous irrigation day.
Runtime resulting from a station that is manually activated via the output hardware switch will not
be captured.
Disable: Disable station operation by selecting Yes.
Resume station operation by s electing No.
S016 100% 1STSTLAWN
Decoder Addr: 38684
Dec Sta: 4 Board: 1
Disable: No
Hold: Use this menu item to delay operation for this station. Select the hold duration from 01–30 days,
Permanent or None. is option is useful when a specic station needs to be deactivated without
aecting any of the programs. is does not aect manual starts from the front panel.
Capacitor
Voltage
Must be set to 15V only.
Dec Addrss: Shows the 5-character address of the decoder module, is downloaded from Lynx.
Dec Oset: Shows the ouput number (1,2,3, or 4), is downloaded from Lynx.