Modes of Operation
e Remote Gateway can be placed in three operating modes: Central mode, Local mode and O mode. In all three modes,
the gateway will accept communications from Lynx
®
. Select the mode of operation by pressing Satellite Settings and
selecting Comm Mode. Select from the three modes using the Input Dial .
Central Mode - When placed in Central Mode, the gateway will allow Lynx to download irrigation programs, edit time and
date and modify the gateways operation mode. If communication between central and gateway is interrupted for more than
one hour, the Central Mode LED indicator will start ashing until communication is reestablished.
Local Mode - When placed in Local mode, the gateway will execute previously downloaded or locally congured irrigation
programs. In this mode, the gateway will allow the central to edit time, date and operation mode but will not allow
modication of settings aecting irrigation programs.
O Mode - When placed in O mode, the gateway will not execute any watering operation whether it is program or
manually initiated. Any watering operation will terminate once the gateway is placed in O mode. Watering operations will
resume once the gateway is placed back to Central or Local mode. In this mode, the gateway will allow the central to edit
time, date and operation mode but will not allow modication of settings aecting irrigation programs.
General Editing
Pressing a menu key on the Remote Gateway will display menu items. Items with elds containing values that can be edited
are called Entry Fields. Use the Arrow Keys
to navigate through the menus and entry elds. Modify
any selected value by scrolling through the selection using the Input Dial
. Values will be saved automatically
when you exit an entry eld or press another menu key. Pressing the HOME button will also save any modication
and revert back to Home display.
Additionally, if no keypad activity is detected within ve minutes, the gateway will automatically save any modications and
revert back to Home display.