Installation Guide
Installation of this heating product shall be in accordance with
manufacturer’s instructions and regulations of the authority having
jurisdiction.
Installation of this heating product shall be in accordance with article 424
Section IX of the National Electrical Code, ANSI/NFPA 70.
Heating elements should not be installed at or below 32 °F (0 °C).
Before installation, ensure that the electrical capacity is sufficient for the
total output of this film.
Jobsite must be clean before Dream Heat gets installed. Any conductive
sharp debris can pierce through the film and create potential shock hazard.
Damaged films must be discarded.
Dream Heat should be installed on properly prepared stable sub-floors. Do
not use other adhesives or nails with the product.
Do not modify the wirings and solely use the wire for Dream Heat. Do not
branch them off and connect other electrical device to the circuit in use for
Dream Heat.
All wirings, fuses and/or circuit breakers must conform to the National
Electrical Code requirements.
Preparation
Materials
Dream Heat
Thermostat