20. Never move the unit while it is burning; 
21. Do not use close to any equipment using oxygen tank. 
General Operation 
Be sure to remove all wrapping, labels, stickers and packaging components 
around the unit and make sure there are no flammable materials in close 
proximity prior to use. 
Follow the directions in this Installation and Operation Manual at all 
times. 
WARNING 
THIS APPLIANCE HAS NOT BEEN TESTED FOR USE WITH DOORS. TO REDUCE THE RISK 
OF FIRE OR INJURY, DO NOT INSTALL DOORS. 
Filling 
CAUTION: Never fill the burner while still in operation, whether or not a 
flame is visible or while the burner is still very hot. 
To facilitate the filling process, remove the protective glass.  
Fill up the burner compartment with Eco-Feu ethanol using the Eco-Feu 
pouring spout equipped with a valve, making sure *NOT* to exceed the 
maximum filling mark (MAX) indicated inside the burner; 
Once filled, put the protective glass back into position. 
Any spilt ethanol fuel must be cleaned immediately with a dry absorbent 
cloth; After cleaning, wash the absorbent cloth thoroughly with water to 
rinse off any ethanol residue. 
By keeping the unit clean of any ethanol residue, it will prevent the 
ignition of residue outside of the burner when it is lit; 
Avoid any contact of ethanol to your skin or eyes. In case of skin or eye 
contact, flush the exposed part thoroughly with cool water for 15 minutes; 
Avoid ingesting and directly inhaling; immediately contact a physician or a 
Poison Control Centre if physical symptoms caused by inappropriate handling 
of ethanol requires medical attention; 
Make sure not to spill ethanol on carpets, lacquered floors, furniture, and 
other surfaces as ethanol spill could cause surface discolouration and 
damage; 
Keep the ethanol in its closed ethanol container.  
Always store the ethanol container in a secure place out of the reach of 
children and pets. 
WARNING 
THIS APPLIANCE HAS NOT BEEN TESTED WITH AN UNVENTED GAS LOG SET. TO REDUCE 
RISK OF FIRE OR INJURY, DO NOT INSTALL AN UNVENTED GAS LOG SET INTO THIS 
APPLIANCE. 
Lighting 
BEFORE LIGHTING MAKE SURE THE PROTECTIVE GLASS IS IN THE CORRECT POSITION. 