Installation Instructions

LED Panel Light InstallationInstructions
Thanks for using our products. Please read these installation i nstructi ons
before installing the luminaire, and keep them for future reference.
Warning
Luminaire must be installed, checked and repaired by an authorized
electrician.
This product must be installed in accordance with the applicable
installation code by a person familiar with the construction and
operation of the product and the hazards involved.
For proper operation, make sure to connect the luminaire to the
proper voltage and install it according to these instructions.
For safety purposes, cut off the power and allow the luminaire to cool
before installing or removing it.
Don’t install the panel light to an unstable ceiling or near combustible
materials.
Cut off the power if there are any unexpected occurrences.
Do not alter or modify the luminaire or change any of the components.
Do not use the luminaire under conditions of direct sunlight
.
Technical Data
Product Name
Dimensions
Input Voltage Fr eque nc y
PowerConsumption
InstallationMethod
LED Panel Light
303x1213mm
120-277Vac 50-60Hz
40W
603x603mm
120-277Vac 50-60Hz
40W
603x1213mm
120-277Vac 50-60Hz
50W
WireConnection
Installation Instruction
Recessed In Plaster Or Grid Ceilings
Surface-Mounted Installation
Utilization of EarthquakeClips
panel until facingperpendicular
to the panelsurface.
Pull earthquake clip away from
Bend earthquake clip 90°.
Install panel light on grid supports.
Assemble the mounting brackets.
Drill 4 small holes in the ceiling
surface, and then install the
rubber plugs and the brackets
in the ceiling.
Remove one side of the brackets.
Connect the panel light to an
incoming power line.
Install the panel light into the
brackets.
Install the remaining side of the
bracket.
Non-Dimmable 0/1-10vdc Dimmable
LISTED
LED lum inaire
Recessed in plaster or
grid ceiling
Utilization of earthquake
Clips
Surface mounted
Lay in thepanel lighton
the ceiling surface or
grid.
For installation in plaster
ceilings, cut an opening
of the appropriate size,
and then connect the
panel light to anincoming
power line.
Using the toggle
switch(located in the
j-box), tune to the
desired color
temperature.
Rotate the panel light
by 45degrees.
Pass the panel through
the ceilingsurface.
SKU 348-0123
5 YEAR LIMITED WARRANTY

Summary of content (2 pages)