Result Register Overview
With different settings in the sequencer register 0x000B the FH3D02 can be used for various applications.
Depending on the TableSelect settings in register 0x000B the results in registers 0x0111 – 0x0114,
0x0120 – 0x124 can hold different magnetic values. The following table gives an overview about the
register content in different configurations.
Register
TableSelect
0b00
(1 kHz)
TableSelect
0b01
(0.5 kHz)
TableSelect
0b10
(1 kHz)
TableSelect
0b11
(1 kHz)
0x0110
(Temp)
Temperature
Temperature
Temperature
Temperature
0x0111
(Bi0)
Pixel 0
Bz
0
Pixel 1
By
1
Pixel 0
Bz
0
Pixel 0
By
0
0x0112
(Bi1)
Pixel 0
Bz
0
Pixel 0
By
0
Pixel 1
Bz
1
Pixel 1
By
1
0x0113
(Bj0)
Pixel 0
Bx
0
Pixel 1
Bx
1
Pixel 0
Bx
0
Pixel 0
Bx
0
0x0114
(Bj1)
Pixel 0
By
0
Pixel 0
Bx
0
Pixel 1
Bx
1
Pixel 1
Bx
1
0x0120
(Mag)
CORDIC
Magnitude
(1)
CORDIC
Magnitude
(1)
CORDIC
Magnitude
(1)
CORDIC
Magnitude
(1)
0x0121
(Ang)
CORDIC
Angle
(2)
CORDIC
Angle
(2)
CORDIC
Angle
(2)
CORDIC
Angle
(2)
0x0122
Linearized
CORDIC Angle
(3)
Pixel 1
Bz
1
(4)
Linearized
CORDIC Angle
(3)
Linearized
CORDIC Angle
(3)
0x0124
-
Pixel 0
Bz
0
(4)
-
-
Output Register
Overview
(1) For CORDIC magnitude calculation and input components refer to chapter 5.1.9
(2) For CORDIC angle calculation and input components refer to chapter 5.1.10
(3) For angle linearization refer to chapters 5.1.11 and 7.8.
(4) For magnetic field components in special function mode refer to chapters 5.1.11 and 5.1.12.