Data Sheet
Seite 18 von 44
Copyright LZE GmbH 2021
List of Registers
Eine gemeinsame Initiative von
5.1.4
0x0110 (read only) – Temperature Sensor
During every measurement cycle the internal temperature is measured sequentially with the magnetic
values. The temperature value is used for internal compensation of magnetic sensor offsets and
sensitivity drifts and is also available in output register 0x0110.
Bit
Symbol
Description
D15 (MSB)
– D0 (LSB)
T
“Temperature”
Output value of the internal temperature sensor. 16 bit signed
integer value in two’s complement representation.
Conversion (typical): T [°C] = T [LSB] / 200 [LSB/°C] + 25°C
0x0110 Bits
5.1.5
0x0111 (read only) – Bi
0
Magnetic Field
Depending on the table selection (Bits TableSelect in register 0x000B) the Bi
0
output register can hold
different magnetic field components. For an overview of the Bi
0
contents refer to chapter 5.2.
Bit
Symbol
Description
D15 (MSB)
– D0 (LSB)
Bi0
“Bi
0
”
Output value of magnetic field sensor. 16 bit signed integer
value in two’s complement representation.
For explanation of the actual magnetic direction refer to chapter
5.2.
Conversion (typical): Bi
0
[µT] = Bi
0
[LSB] * 4 [µT/LSB]
0x0111 Bits
5.1.6
0x0112 (read only) – Bi
1
Magnetic Field
Depending on the table selection (Bits TableSelect in register 0x000B) the Bi
1
output register can hold
different magnetic field components. For an overview of the Bi
1
contents refer to chapter 5.2.
Bit
Symbol
Description
D15 (MSB)
– D0 (LSB)
Bi1
“Bi
1
”
Output value of magnetic field sensor. 16 bit signed integer
value in two’s complement representation.
For explanation of the real magnetic direction refer to chapter
5.2. Conversion (typical): Bi
1
[µT] = Bi
1
[LSB] * 4 [µT/LSB]
0x0112 Bits