Data Sheet

Table Of Contents
Seite 43 von 44
Copyright © 2021, LZE GmbH
www.lze-innovation.de
Additional Features
7.9
Magnet Lost Setting
At every measurement the magnetic field magnitude is compared to an adjustable value and the flag
MagLost in register 0x0107 is set if the magnitude falls below this value.
In order to avoid a toggling flag on the edge of this limit a hysteresis can be set.
Bit
Symbol
Description
D15
D11
r
(Reserved. Always 0)
D1
0
D8
Hyst
Hysteresis
Hysteresis around the Magnet Lost Limit. It is calculated by
Hyst
MgnLostLmt
2
1
16
Factory setting is 1, which corresponds to approx. 0.43 mT.
D
7
D0
MgnLostLmt
Magnet Lost Limit
If the bits <13:6> of the Magnetic Field Magnitude (register
0x0120) is lower than
MgnLostLmt the error flag MagLost in
register 0x0107 is set.
Factory setting is 3, which corresponds to approx. 0.93 mT.