Additional Features
Example data of real magnet in gradient mode. The standard CORDIC angle “Gradient” jumps between +/-180° if the Bj component
crosses 0. “MgnRngExt” shows a valid angle without ambiguity by offering a range of +/-288°.
Please note: Bi and Bj are not directly accessible by SPI.
-32768
-24576
-16384
-8192
0
8192
16384
24576
32768
-10 -05 00 05 10
Value [LSB]
Position [mm]
Register values vs Position (gradient mode)
0x111 (Bi0) 0x112 (Bi1) 0x113 (Bj0)
0x114 (Bj1) 0x121 Gradient 0x121 MgnRngExt