Data Sheet
Table Of Contents
- 1 FH3D02 Overview
 - 2 Characteristics
 - 3 Package and Circuit Connection
 - 4 SPI Communication
 - 5 List of Registers
- 5.1 Measurement Register Contents
- 5.1.1 0x000B (read/write) – Measurement Control
 - 5.1.2 0x000E (read/write) – Measurement Start
 - 5.1.3 0x0107 (read only) – Status Register
 - 5.1.4 0x0110 (read only) – Temperature Sensor
 - 5.1.5 0x0111 (read only) – Bi0 Magnetic Field
 - 5.1.6 0x0112 (read only) – Bi1 Magnetic Field
 - 5.1.7 0x0113 (read only) – Bj0 Magnetic Field
 - 5.1.8 0x0114 (read only) – Bj1 Magnetic Field
 - 5.1.9 0x0120 (read only) – Magnetic Field Magnitude
 - 5.1.10 0x0121 (read only) – Magnetic Field Angle
 - 5.1.11 0x0122 (read only) – Linearized Angle / Bz1 Field (Special Function Mode)
 - 5.1.12 0x0124 (read only) – Bz0 Magnetic Field (Special Function Mode)
 
 - 5.2 Result Register Overview
 
 - 5.1 Measurement Register Contents
 - 6 Measurement Modes
- 6.1 Single Magnetic Probe
 - 6.2 Dual Magnetic Probe
 - 6.3 Linear Position or Off-Axis Angle Sensor (Absolute Field Values, Magnet On-Top)
 - 6.4 Linear Position or Off-Axis Angle Sensor (Gradient Field Values, Magnet On-Top)
 - 6.5 Linear Position or Off-Axis Angle Sensor (Absolute Field Values, Magnet At-The-Side)
 - 6.6 Linear Position or Off-Axis Angle Sensor (Gradient Field Values, Magnet At-The-Side)
 
 - 7 Additional Features
 - 8 LZE GmbH
 
Seite 34 von 44 
Copyright © 2021, LZE GmbH 
www.lze-innovation.de 
Additional Features
Timing diagram of 3 PWM cycles. t
1
/t and t
2
/t define the duty cycle. The last cycle represents an error state at which no PWM edge 
is generated. 
Characteristic curve of the PWM duty cycle vs linearized angle value. The black line represents the maximum possible PWM range. 
The green curve shows limited min and max values. 
Please note: 
Even if a high PWM frequency is used the output update rate is defined by the internal 
measurement cycle. Hence several equal output values will be generated. For analog voltage 
emulation by using a low pass filter at the PWM output this might still be a preferred setting. 
At low PWM frequencies the PWM will only represent the currently valid angle. There is no 
averaging of several measurement values even if the internal measurement rate is higher than 
the PWM frequency. 
The PWM settings can be read by SPI at register 0x000D but only be set at the appropriate 
EEPROM address 0x00D. 
The 0% and 100% levels of the PWM duty cycle are always at ±180° of the linearized angle. 
Hence the zero-point of the PWM can not be chosen arbitrarily. It is only possible to shift the 
range around 50% slightly by using the linearization table. 
The PWM can only be activated if bit 11 of the lock mode word is set to 1 (refer to 7.3). 
7.4.1  Stand-Alone Operation with PWM Output 
It is possible to use the FH3D02 as stand-alone sensor with PWM output. In this case the following steps 
are advised: 
1.  Set a safe lock mode with PWM mode enabled, e.g. 0xDF68 (see chapter 7.3). 
2.  Set an appropriate measurement configuration by modifying EEPROM address 0x00B (see 
5.1.1). 
3.  Set magnet lost limit (see 7.9) if a different minimum field strength than 1 mT is needed. 
4.  Calculate and generate an appropriate linearization table and store it in the EEPROM. 
5.  Configure and enable the PWM by modifying EEPROM address 0x00D (see above). 
6.  Enable the continuous measurement mode: EEPROM address 0x00E (see 5.1.2). 
7.  Set a safe application lock mode with PWM enabled, e.g. 0xDFFD (see chapter 7.3). 
8.  Reboot the device. After the reset cycle the automatic measurement mode will commence and 
the PWM output will be activated. 
PWM 
t = 1/f
PWM 
t = 1/ f
PWM 
t
1 
…
t = 1/ f
PWM 
…
t
2 
-32767                    0                    32767 
LinAngle [LSB]
PWM Duty Cycle 
0%                        50%                   100% 