Data Sheet
Table Of Contents
- 1 FH3D02 Overview
 - 2 Characteristics
 - 3 Package and Circuit Connection
 - 4 SPI Communication
 - 5 List of Registers
- 5.1 Measurement Register Contents
- 5.1.1 0x000B (read/write) – Measurement Control
 - 5.1.2 0x000E (read/write) – Measurement Start
 - 5.1.3 0x0107 (read only) – Status Register
 - 5.1.4 0x0110 (read only) – Temperature Sensor
 - 5.1.5 0x0111 (read only) – Bi0 Magnetic Field
 - 5.1.6 0x0112 (read only) – Bi1 Magnetic Field
 - 5.1.7 0x0113 (read only) – Bj0 Magnetic Field
 - 5.1.8 0x0114 (read only) – Bj1 Magnetic Field
 - 5.1.9 0x0120 (read only) – Magnetic Field Magnitude
 - 5.1.10 0x0121 (read only) – Magnetic Field Angle
 - 5.1.11 0x0122 (read only) – Linearized Angle / Bz1 Field (Special Function Mode)
 - 5.1.12 0x0124 (read only) – Bz0 Magnetic Field (Special Function Mode)
 
 - 5.2 Result Register Overview
 
 - 5.1 Measurement Register Contents
 - 6 Measurement Modes
- 6.1 Single Magnetic Probe
 - 6.2 Dual Magnetic Probe
 - 6.3 Linear Position or Off-Axis Angle Sensor (Absolute Field Values, Magnet On-Top)
 - 6.4 Linear Position or Off-Axis Angle Sensor (Gradient Field Values, Magnet On-Top)
 - 6.5 Linear Position or Off-Axis Angle Sensor (Absolute Field Values, Magnet At-The-Side)
 - 6.6 Linear Position or Off-Axis Angle Sensor (Gradient Field Values, Magnet At-The-Side)
 
 - 7 Additional Features
 - 8 LZE GmbH
 
Seite 30 von 44 
Copyright © 2021, LZE GmbH 
www.lze-innovation.de 
Additional Features
The following table gives an overview about the content of different address ranges in the EEPROM.  
Address 
range 
Content 
Note 
0x00
1 – 
0x00F
SPI register 
initialization 
At the reset cycle the content of this EEPROM 
address range is copied to the SPI accessible 
volatile memory and will be used during normal 
operation. 
0x010 – 
0x01F 
Sensor calibration data
Do not access this address range. Any modification 
will result in device malfunction! 
0x020
Lock mode
Definition of EEPROM access restrictions. Refer to 
7.3 for further information. 
0x021 – 
0x026 
Reserved
Do not access this address range. Any modification 
will result in device malfunction! 
0x027 
Analog calibration data 
Write access to this address is prevented. 
0x028 – 
0x02D 
Reserved
Do not access this address range. Any modification 
will result in device malfunction! 
0x02E 
– 
0x02F
Unique ID
Every device of a production lot has a unique 32-bit 
identification number. It can be used for 
traceability 
purposes. The production lot can be identified by the 
date code on every device.
Write access to the ID is prevented. 
0x030 – 
0x057 
Analog and sensor 
calibration data 
Do not access this address range. Any modification 
will result in device malfunction! 
0x058 – 
0x05E 
Reserved
Do not access this address range. 
0x05F – 
0x07F 
Angle linearization table
Refer to 
7.8 for further information. 
0x080 – 
0x0FF 
Sensitivity correction 
tables 
Do not access this address range. Any modification 
will result in device malfunction! 
0x100 – 
0x1FF 
Measurement sequence 
definitions 
Do not access this address range. Any modification 
will result in device malfunction! 
EEPROM address 