Data Sheet

Table Of Contents
Seite 25 von 44
Copyright © 2021, LZE GmbH
www.lze-innovation.de
Measurement Modes
6.4
Linear Position or Off-Axis Angle Sensor
(Gradient Field Values, Magnet On-Top)
With this setting a linear position measurement or an off-axis angle measurement is feasible. The
gradient mode makes the angle value independent from homogeneous external fields. A linearization
table can be used for both applications to allow for a linear output curve (see chapter 7.8).
6.4.1 Application Example
Magnet configuration examples in zero position for gradient operation mode
6.4.2 Settings
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Setting
0
0
0
0
MgnRngExt
0
0
0
1
0
0
1
0
0
Rdy2hZ
0
Default 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0
Register 0x000B bit settings
(1) (2)
6.4.3 Output Registers
0x0112
0x0113
0x0120
0x0121
0x0122
Pixel 1
Bz
1
Pixel 0
Bx
0
Magnitude
(4)
Angle
(4)
Linearized
angle
(3)
Output
Registers
(4) CORDIC magnitude: 0.8234
(


)
+
(


)
CORDIC angle: 2
(


)
,
(


)
6.4.4 References
(1) see chapter 7.5 for explanation of bit Rdy2hZ
(2) see chapter 7.7 for explanation of bit MgnRngExt
(3) see chapter 7.8 for explanation of angle linearization
X
Z
Y
ball C1
Pixel 1
ball C1
Pixel 1
Pixel 0
Pixel 0