Data Sheet
Table Of Contents
- 1 FH3D02 Overview
- 2 Characteristics
- 3 Package and Circuit Connection
- 4 SPI Communication
- 5 List of Registers
- 5.1 Measurement Register Contents
- 5.1.1 0x000B (read/write) – Measurement Control
- 5.1.2 0x000E (read/write) – Measurement Start
- 5.1.3 0x0107 (read only) – Status Register
- 5.1.4 0x0110 (read only) – Temperature Sensor
- 5.1.5 0x0111 (read only) – Bi0 Magnetic Field
- 5.1.6 0x0112 (read only) – Bi1 Magnetic Field
- 5.1.7 0x0113 (read only) – Bj0 Magnetic Field
- 5.1.8 0x0114 (read only) – Bj1 Magnetic Field
- 5.1.9 0x0120 (read only) – Magnetic Field Magnitude
- 5.1.10 0x0121 (read only) – Magnetic Field Angle
- 5.1.11 0x0122 (read only) – Linearized Angle / Bz1 Field (Special Function Mode)
- 5.1.12 0x0124 (read only) – Bz0 Magnetic Field (Special Function Mode)
- 5.2 Result Register Overview
- 5.1 Measurement Register Contents
- 6 Measurement Modes
- 6.1 Single Magnetic Probe
- 6.2 Dual Magnetic Probe
- 6.3 Linear Position or Off-Axis Angle Sensor (Absolute Field Values, Magnet On-Top)
- 6.4 Linear Position or Off-Axis Angle Sensor (Gradient Field Values, Magnet On-Top)
- 6.5 Linear Position or Off-Axis Angle Sensor (Absolute Field Values, Magnet At-The-Side)
- 6.6 Linear Position or Off-Axis Angle Sensor (Gradient Field Values, Magnet At-The-Side)
- 7 Additional Features
- 8 LZE GmbH
Seite 14 von 44
Copyright © 2021, LZE GmbH
www.lze-innovation.de
List of
Registers
5
List of Registers
Following table shows all available registers for communication with the sensor via SIP. For detailed
description of the register content and respective bit assignment go to the specified chapters.
Register
Read / Write
Description
Refer to chapter
0x0004
Read & Write
Clock configuration register
7.6
0x000B
Read & Write
Measurement control register
5.1.1
0x000D
Read
PWM configuration register
7.4
0x000E
Read & Write
Measurement start register
5.1.2
0x0030
Write
EEPROM write/read address register
7.2
0x0031
Write & Read
EEPROM write/read data register
7.2
0x0107
Write
Magnetic measurement result status
5.1.3
0x0108
Read
CRC calculation result
4.2.3
0x0110
Read
Temperature measurement result
5.1.4
0x0111
Read
Magnetic measurement result Bi0
5.1.5
0x0112
Read
Magnetic measurement result Bi1
5.1.6
0x0113
Read
Magnetic measurement result Bj0
5.1.7
0x0114
Read
Magnetic measurement result Bj1
5.1.8
0x0120
Read
Measurement result magnitude
5.1.9
0x0121
Read
Measurement result angle
5.1.10
0x0122
Read
Measurement result linearized angle /
Special function: Magnetic measurement
result Bz1
5.1.11
0x0124
Read
Special function: Magnetic measurement
result Bz0
5.1.12
Register
Overview