Datasheet

Fan Model :
FD129225LS-N(1A3K)
Test Date :
2003/12/26
Key Point :
FD129225LS-N(1A3K)
Order No. :
9225-N
Blade No. : 7 Test No. :
YS
Motor Poles : 4 Method :
Constant Voltage
Rating Voltage(V) : 12 VDC Tunnel Setup : Inlet Chamber Type
Rating Current(A) : 0.10
Temperature() : 26
R.H.(%) :
45
Rating Speed(rpm) : 1800 Barometric Pressure(mmHg) : 763.9
Test Voltage(V) : 12 VDC Acoustic ( dB(A)/1M ):25.0dB(A)
Max. Flow rate(CFM) : 37.253 Mea. Distance(M): 1
Max. Flow rate(m
3
/min) :
1.055
Background Noise:10.0dB(A)
Max. Pressure(in-H
2
O) :
0.057
Vibration Level (mm/sec
2
): N / A
Max. Pressure(mm-H
2
O)
:
1.440 Remark:
Voltage Current Power Speed
CFM m3/min in-H2O mm-H2O V A W rpm
1 37.253 1.0546 0.0000 0.000 12.00 0.080 0.96 1966
2 27.921 0.7904 0.0170 0.432 12.00 0.082 0.98 1856
3 18.606 0.5267 0.0256 0.650 12.00 0.082 0.98 1841
4 9.324 0.2640 0.0353 0.897 12.00 0.085 1.02 1704
5 0.000 0.0000 0.0567 1.440 12.00 0.088 1.06 1560
Examiner: Tester:
1
Fan Performance Curve
Yen Sun Technology Corp.
Fan Performance Test Report
Curve Pts
Flowrate Static Pressure
Approver:
劉智光 許志聰 張馥怡
0.0000
0.0150
0.0300
0.0450
0.0600
0.000 10.000 20.000 30.000 40.000
Flow Rate (CFM)
Static Pressure (inH2O)
FD129225LS-N(1A3K)